Venting
Frequency: Seasonally
By: Homeowner
Tools needed: Protective gloves and safety glasses.
• Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
• Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds).
• Inspect for corrosion or separation.
• Verify weather stripping, sealing and fl ashing remains
intact.
• Inspect draft shield to verify it is not damaged or missing.
PowerFlow™ Heat Management System
WARNING! Risk of Fire! Either the HEAT-ZONE-PRIMO
or the HEAT-OUT-PRIMO must remain ON during opera-
tion of the appliance. Overheating will occur. Appliance
will shut down.
HEAT-ZONE-PRIMO
Frequency: Seasonally
By: Homeowner
Tools Needed: Protective gloves and safety glasses.
• Inspect venting and air register(s) clean and free of any
blockage or obstructions.
• Verify fan is working properly.
HEAT-OUT-PRIMO
Frequency: Seasonally
By: Homeowner
Tools Needed: Protective gloves and safety glasses.
• Inspect venting and termination cap for blockage or
obstructions inside such plants, bird nests, leaves, snow,
debris, etc.
• Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds).
• Verify fan is working properly.
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Owner's Manual • 2310-971 Rev. G • 9/15
Power Vent System
Frequency: Seasonally
By: Homeowner
Tools Needed: Protective gloves and safety glasses.
• Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
• Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds).
• Verify fan is working properly.
Note: The PRIMO must be power-vented using either a
PVI-SLP system or a PVLP-SLP system.
WARNING! Risk of Shock! Before performing any main-
tenance or repair to the power vent assembly, make sure
electrical power to the fi replace is disconnected.
Access Panel: Inspect at least annually. Ensure vertical
gap, located between transition media tray and bottom
edge of the barrier glass, is free of dust and debris.