Takagi T-H2-DV Installation Manual And Owner's Manual page 44

On-demand condensing water heater
Hide thumbs Also See for T-H2-DV:
Table of Contents

Advertisement

If there is a problem with the installation or the T H2 DV/T H2 OS, it will display a numerical
error code on the 7 seg LED of the computer board or the TM RE30 (if installed) to
communicate the source of the problem.
Error
Code
031
Incorrect dipswitch settings
101
Warning for the "991" error code
111
Ignition failure
121
Loss of flame
311
Output thermistor failure
321
Inlet thermistor failure
331
Mixing thermistor failure
341
Exhaust thermistor failure (Only T H2 DV)
391
Air fuel Ratio Rod Failure
441
Flow Sensor Failure (Only Easy Link system)
510
Abnormal Main Gas Valve
551
Abnormal Gas Solenoid Valve
611
Fan Motor Fault
621
Exhaust fan motor Fault (Only T H2 DV)
631
Abnormal External Pump
Water Control Valve Fault (Flow Adjustment function)
651
(Only Easy Link system)
661
Water Control Valve Fault (Bypass valve function)
701
Computer board Fault
711
Gas Solenoid Valve drive circuit failure
721
False Flame Detection
Miscommunication between T H2 DV/T H2 OS and
741
TM RE30
761
Miscommunication in Easy Link
941
Abnormal exhaust temperature (Only T H2 DV)
991
Imperfect combustion
FAULT ANALYSIS OF ERROR CODES
Malfunction description
44
Page
Troubleshooting
Diagnosis
Check the dipswitch
settings on PCB
Call TAKAGI
Technical Dept.
at 1 888 882 5244
Check gas supply
Call TAKAGI
Technical Dept.
at 1 888 882 5244
Lower
the
set
temperature
Call TAKAGI
Technical Dept.
at 1 888 882 5244

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-h2-os

Table of Contents