No.
Parameter
070 Line Error
071 Total Error
072 Continuous Error 1 = Off (unlimited)
073 Error Detect
074 RTN Receive
075 Coding
076 Batch TX
077 RX JAM Length
078~
Not Used
079
080 Doc Top Feed
081 Doc End Feed
082 JAM Length
083 Not Used
084 Line As No Paper 1 = Ring (ring)
085~
Not Used
086
087 Darker Level
088 Normal Level
089 Lighter Level
Function Parameter Table
Selections
128 lines
256 lines
512 lines
1024 line
2048 lines
Off
(will not disconnect line)
1 = 5%
2 = 10%
3 = 15%
4 = 20%
2 = 3 lines/STD
3 = 6 lines/STD
4 = 12 lines/STD
1 = Lines
2 = Rate
1 = Disconnect
2 = Continue
1 = MH (MH only)
2 = MR (MH or MR)
3 = MMR
(MH or MR or MMR)
4 = JBIG
1 = Off
2 = On
1 = Off (unlimited)
2 = 2 m
-99
~
+99
-90
~
+127
1 = 1 m
2 = 2 m
2 = Busy (keep line busy)
0 = Lightest Contrast
~
15 = Darkest Contrast
1. Selects the line disconnect condition during
reception. If the number of line errors exceed this
setting, the unit will disconnect the line.
Press "V" or "/\ " to select the symbol rate.
2. Selects the transmit condition of RTP/PIP or
RTN/PIN.
(Available if No.73 Error Detect is set to "LINES")
(See Note 1)
Selects the transmit condition of RTP/PIP or RTN/
PIN.
(Available if No.73 Error Detect is set to "RATE".)
(See Note 2)
Selects the continuous total error criteria of Off/3/6
or 12 lines in Standard mode. If continuous total
error exceeds this setting, the unit will transmit
RTN/PIN.
(Available if No.73 Error Detect is set to "RATE".)
Selects the error detect condition Lines/Rate.
Selects whether to disconnect the phone line or
continue when "RTN" is received.
Selects the coding scheme.
Selects whether the batch transmission is available.
Selects the maximum length of a received
document that can be printed.
Adjusts the distance between the scanning sensor
ON position and the scanning start position.
Adjusts the distance between the scanning sensor
OFF position and the scanning end position.
Selects the maximum length of the original that can
be scanned.
Selects whether to ring or send a busy tone to the
remote station when the recording paper runs out or
the unit cannot receive because of any trouble.
Selects the contrast level.
0
15
← →
Lightest
Darkest
160