Toshiba E-STUDIO190F Service Manual page 125

Plain paper facsimile
Hide thumbs Also See for E-STUDIO190F:
Table of Contents

Advertisement

Code
Mode
494
RCV
495
XMT
RCV
496
XMT
501
XMT/
RCV(V.34)
502
XMT/
B, C, D During reception, CD turned OFF
RCV(V.34)
503
XMT/
B, C, D CS of modem is not able to turn
RCV(V.34)
504
RCV/V.34
(Polling)
505
XMT/V.34
(Polling)
540
XMT ECM
541
XMT ECM
542
XMT ECM
543
XMT ECM
544
XMT ECM
550
RCV ECM
554
RCV ECM
555
RCV ECM
570
RCV
571
XMT
580
XMT
581
XMT
Fax Information Codes
Phase
Description of Problem
C
Interval between two EOLs was
more than 10 sec. when receiver
received message data.
C
During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
C
CS of modem is not able to turn
ON.
B
Remote unit does not have
compatible Modem.
or continued ON for long time.
During communication, lost loop -
current.
ON during training.
B
Polling is rejected from the remote
station.
B
Polling XMT is rejected.
B
No response after transmitting 3rd
CTC or DCN received.
D
No response after transmitting 3rd
EOR or received DCN.
D
No response to the 3rd RR
transmitted or received DCN.
D
T5 timer (60 sec.) elapsed without
MCF.
D
Stopped Transmission after EOR
Transmission.
C
Timer between frames in phase C
has elapsed.
D
Transmitted ERR after receiving
EOR.
D
Transmitted PIN after receiving
EOR.
B
Password or machine code did not
match during remote diagnostic
communication.
B
Remote unit did not have the
remote diagnostic function.
B
Sub-address transmission to a unit
that has their DIS bit 49 (NSF bit
155) OFF.
B
Sub-address Password
transmission to a unit that has their
DIS bit 50 (NSF bit 156) OFF.
Transmitter is defective.
Line quality is poor. (EOL is damaged
due to line noise)
SC PCB or FXB PCB is defective.
Line is disconnected.
Transmitter is defective.
SC PCB or FXB PCB is defective.
FXB PCB is defective.
Line is disconnected.
Transmitter is defective.
SC PCB or FXB PCB is defective.
FXB PCB is defective.
Line is disconnected.
No polling original is set.
No polling original is set.
Incompatible interface.
Line is faulty.
FXB PCB abnormal.
Remote unit is abnormal.
Remote unit is abnormal.
Line is faulty.
FXB PCB abnormal.
Defective remote station.
Line is faulty.
Line is faulty and Operator Call
requested by RX side.
Sub-address transmission to a unit that
has no Sub-address function.
Sub-address transmission to a unit that
has no Sub-address function.
125
Cause

Advertisement

Table of Contents
loading

Table of Contents