2. Remove The Flame Tube.
A. Loosen and Remove the four 5/16 - 24 nuts securing
the Flame Tube in place.
B. Remove the Fame Tube Spacer.
C. Remove the Flame Tube.
D. Clean and inspect the Flame Tube.
E. Clean and inspect the Heat Transfer Tabs welded
inside the Aqua-hot, using a long handled wire brush.
F. Clean and inspect the Flame Tube Spacer.
Flame Tube
Flame Tube
Spacer
Gasket
A
PPENDIX
Flame Tube
®
© 2009 Aqua-Hot
375D Hydronic Heating System Service Manual—Rev. A
E: A
M
NNUAL
AINTENANCE
Figure 96
P
ROCEDURE