Exhaust System ................. 23 Pin-Out Information ..............26 Connecting the 250D to 12V DC Power ........27 Connecting the Aqua-Hot to AC Power ........28 Filling/Purging the Aqua-Hot 250D .......... 29 DANGER signals a situation where immediate risk of serious First Operation ................30 injury or death will result if instructions are not followed.
The Aqua-Hot’s exhaust is HOT and must be kept away from (574-247-9235). heat sensitive material. • DO NOT connect the 12-volt DC power to the Aqua-Hot if the vehicle requires welding. • At maximum operating temperature, the coolant will be very hot and scalding.
Page 4
Aqua-Hot’s boiler tank. based antifreeze and distilled water solution that is stored in the Aqua-Hot’s boiler tank. This fl uid solution must be up to The heater also employs a 12V DC diesel burner as the operating temperature before the Aqua-Hot will provide interior primary heating source.
NOTE: This product label is attached to the side of the listed in the Recreational Vehicle Industry Association’s Aqua-Hot, and provides a ready reference to specifi cations, (RVIA) ANSI/NFPA 1192 Handbook for Recreational Vehicle test standards, and important safety notices.
DO 15. 120V AC Connection NOT remove these panels. Doing so risks irreparable damage to the Aqua-Hot. Only remove the service panel for service. 16. Boiler Tank 17. Domestic Hot-Water Coil 18.
2. Cut out the required mounting fl ange opening Reference Figure 4. 3. Install the fl ange located on the bottom of the Aqua-Hot into the cutout opening. Reference Figure 6 & 7. 4. Take the angle brackets and included ¼-20 bolts and washers.
12.625” 2” 12.57” Figure 4 NOTE: The mounting fl ange of the Aqua-Hot is not centered on the body of the heater. Reference Figure 4 for the correct dimensions to construct the surface on which the Aqua-Hot will be mounted.
Page 9
Support and Clearance Seat the Aqua-Hot in the Flange cutout Coach Bay Floor ¼-20 Bolt and Lock Washer Figure 6 Mounting Brackets on both sides, front, and rear NOTE: Angle mounting bracket must be fl ush to the underside of the coach fl oor and fl ush to the heater fl ange.
Upper Fitting The fl uid expansion bottle is integral to the operation of the Aqua-Hot. It provides an area for hot, expanded fl uid to empty Hot Fluid Line into, and also protects the Aqua-Hot from low-fl uid, which could lead to catastrophic damage of the Aqua-Hot.
NOTE: For the best performance, the fi rst heat exchanger should be placed where heat loss is the greatest. The fi rst heat exchanger will always output the largest volume of heat as compared to subsequent exchangers. Aqua-Hot Unit Heat Exchanger 2 Living Area Heat Exchanger 3...
fl uid pressure to allow the 6th heat exchanger to operate as intended. Aqua-Hot advises against placing a heat exchanger on the slide-out section of any vehicle due to the high probability of damage occurring to the heating loop from moving parts.
When choosing a zone control for the heat exchangers, the guidelines. If a deviation is required, contact Aqua-Hot Heating following guidelines must be adhered to, or the Aqua-Hot will Systems prior to installing these exchangers for express not function correctly in any mode of operation.
fl ow of the plumbing to and from heat exchangers. arrangement. Placement and quantity may vary depending on the coach. 6. Connect and clamp the inlet line from the heater to the Aqua-Hot highest port on the Heating System last heat exchanger to complete the heating Cozy #1 loop.
The electric element will only provide light duty hot water. • The Aqua-Hot is equipped with a pressure relief valve and a The tempering valve is integrated into the cabinet of the tempering valve in order to provide safe hot water without Aqua-Hot, and is set upon departure from the Aqua-Hot factory.
Coach Control Panel Screen: 4. Move both switches to the OFF position by pressing Newer Aqua-Hot units may have a coach touch-screen them in a downward motion. display instead of the interior switch panel. This section is only for the installation and wiring for the interior switch panel.
A 10 Micron diesel fuel fi lter must be installed at the diesel extreme rises in height should be avoided to eliminate fuel source at all times during the operation of the Aqua-Hot any potential air traps. 250D. This fuel fi lter ensures clean fuel is delivered to the fuel nozzle at all times.
Page 22
3. Install and tighten the appropriate fuel fi ttings onto the Aqua-Hot’s fuel ports. 4. Connect the Aqua-Hot’s fuel lines to the fuel tank. 5. Cut the fuel line at the fuel fi lter mounting location and Input from Fuel Output to the connect the fuel lines as illustrated in Figure 32.
Introduction to Wiring Pin-Out Information 200 Series Pin-Out Information The following section serves to provide electrical information particularly pertaining to pin-out confi gurations to assist in correctly wiring the coach-side electrical connections. Installation must be performed by a professional installer or technician as per national/local regulations.
The red (+) wire must be fused with a 25A fuse to protect the Aqua-Hot from an over-current condition. DO NOT connect 12V DC power to the Aqua-Hot if 2. Crimp the appropriate terminals called out in Table 1 to the vehicle requires welding.
Reference Figure 41 A119.2/NFPA 501C Standard on Recreational Vehicles 1993 Edition. 1. Route three 120V AC power source wires to the Aqua-Hot • The boiler must be connected to a 120V AC supply heater. permanently and be protected with a 20A breaker (minimum).
5. Attach the fl uid expansion hose and the expansion bottle to the expansion tank port located on top of the Aqua-Hot. Before the fi rst activation of the Aqua-Hot, fi ll the unit with Secure the hose as shown on Page 9.
Activation Instructions (Burner) 1. Make sure there are no blockages or debris to the exhaust The fi rst start-up of the Aqua-Hot may not light up perfectly. outlet or combustion air inlet. This is normal. On the diesel systems, fuel lines may not have been bled of air prior to the fi...
“GRAS” antifreeze) rated for winterization is used when system overview. winterizing this unit. The warranty does not cover freeze damage. NOTE: The Aqua-Hot can continue to be used for interior heat De-Winterization: once the domestic hot water system has been winterized.
Page 35
“boiler” type antifreeze in the concentrated propylene glycol antifreeze with water; suppliers Aqua-Hot. Propylene glycol is a safer alternative to the more of premixed antifreeze are responsible for the use of high- toxic ethylene glycol antifreeze; however, as mandated by...
Page 36
Generally Recognized As Safe (“GRAS”) by the FDA could Therefore, as water is an excellent heat conductor, it is result in serious bodily harm to damage to the Aqua-Hot added to the mixture. Propylene glycol antifreeze solution, system.
Thus, problems due to improper specifi cations, improper installations, improper use, the use of accessory parts or parts not authorized by Aqua-Hot Heating Systems Inc., repair by unauthorized persons, and damage or abuse of the heater are specially excluded from warranty coverage.