Table 6. LEDs (2 of 2)
LED
State
10/100
Solid
Ethernet
Green
Connection
100
No
Illumination
10/100
Pulsing
Ethernet
Amber
Connection
Solid
Act
Amber
No
Illumination
10/100
Solid
Ethernet
Green
Connection
Lnk
No
Illumination
* A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks
at a more rapid, less constant rate.
NOTE: Whenever the E1 connection has lost link or has presented an E1 Alarm, the
Ethernet link will automatically be disabled (as indicated by solid illumination of the
Ethernet 100, Act and Lnk LEDs). Upon reestablishment of the E1 connection, the
Ethernet link will be reinstated and the Ethernet LEDs will reflect current Ethernet
Status.
Indication
100 Mbps Ethernet
connection is
established
No 100 Mbps Ethernet
connection
Standard operation
Heavy traffic
No activity
Ethernet connection is
established
No Ethernet connection
9
Additional Information
If the Ethernet 100 LED is
illuminated, the Ethernet Lnk
LED will also be illuminated.A
solid green Ethernet 100 LED
can also signify an E1 Alarm.
If the Ethernet 100 LED
remains unlit but the Ethernet
Lnk LED is illuminated then a
connection has been
established at 10 Mbps rather
than 100 Mbps.
Traffic is flowing without any
problems.
A solid amber Ethernet Act
LED can also signify an E1
Alarm.
Either there is no Ethernet link
or a link exists but there is no
activity.
If the Ethernet Lnk LED is
illuminated but not the
Ethernet 100 LED then a
10 Mbps connection has been
established. If the Ethernet
100 LED is also illuminated,
then a 100 Mbps connection
has been established. A solid
green Ethernet Lnk LED can
also signify an E1 Alarm.
The Ethernet 100 and Act
LEDs will remain unlit by
default.