2-3-6 Hold Function Setting
Select
in the General Function setting mode
ACTIONS
Press TARE key
Use ON/ZERO or UNITS key
to key in the parameters
Press TARE key
Key in the parameter "00"
Press TARE key to complete
the general setting procedures
= Hold function disabled
= "Peak hold" mode
Keep displaying the maximum weight when the weight is continually changing
To exit this mode, press any key.
= "Stable hold 1" mode
When the weight is stable, the LCD shows the current weight value. To exit
this mode, press any key.
= "Stable hold 2" mode
When the weight is stable, the LCD shows the current weight value. When the
weight returns to zero (<10d), the hold mode is cancelled automatically.
02005316
DISPLAY
17
to set the hold function.
NOTE
Hold function setting
LCD displays the last parameter setting
Hold function setting
Use
or
ON/ZERO
UNITS
parameters
Default setting = 0
0 ⇒ Hold function disabled
1 ⇒ "Peak hold" mode
2 ⇒ "Stable hold 1" mode
3 ⇒ "Stable hold 2" mode
ON/ZERO key ⇒ Upward key (from 0 to 9)
UNITS key ⇒ Downward key (from 9 to 0)
TARE key ⇒ Move the cursor to right
NET/GROSS key ⇒ Move the cursor to left.
ZSME3000000306
keys to key in the