Cimbali M32 Bistro dt1 Owner's Manual page 42

Hide thumbs Also See for M32 Bistro dt1:
Table of Contents

Advertisement

English
Direct intervention by the customer
In order to avoid unnecessary costs, ensure that the problem occurring in the machine is not included in the following table be fore calling the servicing
department.
DEFECT
The coffee machine does not function and
the indicator (18) is off.
The coffee machine does not heat up.
Leak from edge of filter-holder (7).
Coffee flow time too short.
Water leaks from under the machine.
Tank level indicator light (11) ON flashing,
dispensing disabled.
Boiler level indicator light (12) ON flashing.
Machine at working temperature indicator
light (17) ON flashing.
(*)
1 dispenser unit machines only.
Defects - Malfunctions
CAUSE
No electricity.
Wrong position of the main switch (4).
Only for 2-group machines.
The undercup gasket is dirty with coffee
residue.
Coffee grinds too coarse.
Coffee too old.
Drainage tank clogged.
No water in tank.
Boiler load time-out.
Pressure time-out.
REMEDY
Check that the electricity is on.
Check the position of the main switch (1).
Turn the main switch knob (1) to position 2
Clean with the supplied brush.
Grind the coffee more finely.
Change the coffee.
Clean the tank.
Fill up tank.
Check position of water supply tap.
Switch the machine ON and OFF. If this
doesn't solve the problem, contact the Serv-
ice personnel.
Switch the machine ON and OFF. If this
doesn't solve the problem, contact the Serv-
ice personnel.
English