11 2-Way, 3-Way Valve - Panasonic CS-A7BKP Service Manual

Table of Contents

Advertisement

CS-A7BKP CU-A7BKP5 / CS-A7BKP CU-A7BKP6 / CS-A9BKP CU-A9BKP5 / CS-A9BKP CU-A9BKP6 / CS-A12BKP CU-A12BKP5 / CS-A12BKP CU-A12BKP6

11 2-way, 3-way Valve

Works
Shipping
Evacuation
(Installation and
Re-installation)
Operation
Pumping down
(Transferring)
Evacuation
(Servicing)
Gas charging
(Servicing)
Pressure check
(Servicing)
Gas releasing
(Servicing)
2-way Valve (Liquid Side)
Shaft Position
Close
(With valve cap)
Close
(Counter-Clockwise)
Open
(With valve cap)
Close
(Clockwise)
Open
Open
Open
Open
49
3-way Valve (Gas Side)
Shaft Position
Close
(With valve cap)
Close
(Clockwise)
Open
(With valve cap)
Open
(Counter-Clockwise)
(Connected manifold
Open
With vacuum pump
Open
(With charging cylinder)
Open
(Connected manifold
Open
(Connected manifold
Service Port
Close
(With cap)
Open
(Push-pin)
Close
(With cap)
Open
gauge)
Open
Open
Open
gauge)
Open
gauge)

Hide quick links: