Remote Control Signal Receiving Sound; Indoor Fan Speed Control - Panasonic CS-A7BKP Service Manual

Table of Contents

Advertisement

CS-A7BKP CU-A7BKP5 / CS-A7BKP CU-A7BKP6 / CS-A9BKP CU-A9BKP5 / CS-A9BKP CU-A9BKP6 / CS-A12BKP CU-A12BKP5 / CS-A12BKP CU-A12BKP6
8.8.

Remote Control Signal Receiving Sound

• Long beep sound will be heard when:-
− Stopping the Air Conditioner using ON/OFF switch.
− Stopping the Sleep Mode.
− Stopping the Powerful Mode.
− Stopping the Economy Mode.
• Short beep sound will be heard for others.
• To switch off the beep sound:-
Press the "Automatic Operation Button" continuously for 10 seconds or more ("beep" "beep" will be heard at the 10th second).
Repeat the above if you want to switch ON the beep sound.
However, if the "Automatic Operation Button" has been pressed the Automatic operation will be activated.
If you do not require this operation, you may change it by using the remote control.
8.9.

Indoor Fan Speed Control

Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is shifted automatically between Stop to SHi depend on each operation as shown
below.
Manual Fan Speed Control
Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button at the remote
control.
29