Inspecting FFP

No.
1
Pipe grommet
2
Upper cable terminal grommet
3
Cable terminal grommet
4
O-rings
5
FFP Case
6
FFP assembly
7
Cable terminal assembly (+) (-)
Components
• Wear, deterioration and damage.
Replace if defects are detected.
• Clogging by foreign matter and water.
• Dirt and foreign matter on lower intake port.
• Cracks and damage on upper and lower plastic sections.
• Damage on flat terminal and plug terminal.
• Damage on wiring.
• Scratches or bending on terminals.
• Replace if defects are detected.
Points to check