Testing And Commissioning; Additional Documentation And Informations For The User; Maintenance Frequency - Ravelli o-ring User Manual

Table of Contents

Advertisement

Symbol
Description
Height above the virtual stratum between the build-
A
ing roof or obstacles or adjacent thermal compart-
2
ments in the absence of openings/windows
*)
B
Height above flat roofs or close parapets
*)
If the terrace or flat roof is walkable, the clearance distances should be observed as specified in table 8.
Distance [mm]
X•5 000
5 000 >X•10 000
The symbol Z marks the height (mm) of the obstacle or thermal compartment;
for quotas A
Symbol
Description
Height above the virtual stratum between the
A
building roof or obstacles or adjacent thermal
2
compartments in the absence of openings/windows
Release quotas depend on the distance of chimney terminal free of openings.
IT IS FORBIDDEN TO DISCHARGE FLUES THROUGH A DIRECT SYSTEM
!
OR ANY OTHER DRAIN SYSTEM NOT PROVIDED BY THE STANDARDS
MENTIONED ABOVE

testing and commissioning

Stove commissioning must be preceded by a test that involves the verifi-
cation of the operation of the following elements:
the suitability of the fumes exhaust system;
connection to external air vents, if any;
electric and hydraulic connections;
check that all the materials that make up the smoke duct, flue, chimney
terminal are suitable for use and compliant with standards (fume ex-
haust of a stove with solid fuel).
For heat generating devices powered by mechanical systems testing must
be done according to manufacturer's instructions.
The test is considered successfull when all operation phases are com-
pleted without encountering anomalies.
Distanze da rispettare [mm]
500
1000
Release quota
Z+A
2
J
and J see table 13.
2
Distanze da rispettare [mm]
1000

additional documentation and informations for the user

Upon installation completion, the installer should hand over to the user:
the user's manual of the appliance supplied by the manufacturer;
the technical documentation of the accessories used and subject to
maintenance;
the documentation of the flue exhaust system;
the system booklet (where applicable);
the documentation that certifies installation completion;
The documentation required to cover installer's liability comprises:
detailed description (including photos) of other heat generators present;
declaration of conformity of the state-of-the-art system (D.M. 37/08);
description of overall dimentions, layout or photos regarding the modifi-
cations brought to the layout in case it was necessary to intervene during
installation;
The use of certified material with CE marking (89/106 D.P.R. 246);
any information regarding the warranty;
the date and singature of installer;

maintenance frequency

Maintenance should be carried out periodically, as shown in the table be-
low, and in the manner prescribed by standards and performed by quali-
fied personnel; upon completion a regular intervention report should be
issued.
The installer should ask for the receipt of delivered documenta-
tion and preserve it together with the technical documentation regard-
ing the installation performed.
Type of appliance installed
Pellet appliance
Appliances with air open firebox
Appliances with air close firebox
Water appliances
(fireplaces, thermo-stoves, thermo-cookers)
Boilers
Fume exhaust system
13
USER MANUAL
O-RING
< 15kW
(15 - 35) kW
2 years
1 year
4 years
4 years
2 years
2 years
1 year
1 year
1 year
1 year
1 year
1 year
4t of fuel used 4t of fuel used