Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Belfort
Document n° 979-3 EN ~ 28/02/2000
English
Oil fired stove
Norsk
Model : 174 05 05
(EN 1)
Technical manual
to be saved
by the user
for future reference
Description of the appliance
Installation instructions
Operating instructions
Les Fonderies Franco-Belges
59660 MERVILLE
Spare parts
Phone : 03.28.43.43.43
Fax : 03.28.43.43.99
RC Hazebrouck 445750565B
Subject to modifications

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Belfort 174 05 05 and is the answer not in the manual?

Questions and answers

Summary of Contents for FRANCO BELGE Belfort 174 05 05

  • Page 1 Belfort Document n° 979-3 EN ~ 28/02/2000 English Oil fired stove Norsk Model : 174 05 05 (EN 1) Technical manual to be saved by the user for future reference Description of the appliance Installation instructions Operating instructions Les Fonderies Franco-Belges 59660 MERVILLE Spare parts Phone : 03.28.43.43.43...
  • Page 2: Table Of Contents

    Oil fired stove FRANCO BELGE congratulates you on your choice. FRANCO BELGE, which has been granted the ISO 9001 certification, guarantees the quality of its appliances and is committed to meet its customers’ needs. FRANCO BELGE, which can boast a 75-year experience in the industry of heating devices, uses state-of-the-art technologies to design and manufacture its whole range of products.
  • Page 3: Description Of The Unit

    Oil fired stove BELFORT 174 05 05 1. Description of the unit 1.1. Package 200 mm ¤ 1 package. The stove is supplied completely assembled except the four levelling feet that are placed on the burner. 1.2. Optional equipment ¤ Ground vat ¤...
  • Page 4: Operating Principle

    174 05 05 BELFORT Oil fired stove 1.5. Operating principle Furnace oil is fed to the burner floor (fig. 3) where is it ignited by means of a firestarter (or the Glow-plug ignitor # 6). The heat produced by this flame brings the burner temperature to the required level to vaporize the fuel.
  • Page 5: Mounting The Levelling Feet

    Oil fired stove BELFORT 174 05 05 Figure 6 - Back panel Figure 5 - Top flue outlet 1 - Flue collar 3 - Screws, washers and bolts 2 - Sealing rope - The chimney must be soundly constructed, in order to prevent cold air infiltration.
  • Page 6: Levelling

    174 05 05 BELFORT Oil fired stove Figure 9 - Fitting the tray draught stabilizer (barometric damper) must be installed to the connector pipe. Figure 11 - Gravity or pumped oil supply 2.7. External tank 1 - 2,5 m maxi 5 - Suction pump with 2 - At least 0,25 m reserve and filter...
  • Page 7: Chimney Draught

    Oil fired stove BELFORT 174 05 05 clockwise. - if the flame is too high, reduce the flame by turning the setting screw (# 2) counter clockwise. High setting (Refer to # 3, fig. 12) : - set the regulating knob on “6" and let the burner run for a few minutes.
  • Page 8: Operating Instructions

    174 05 05 BELFORT Oil fired stove 3. Operating instructions 3.1. Fuel Warning : Your stove is fitted with a specific float regulator for a specific oil. ¤ Kerosene 28 sec. (1,8 cst at 25°C) The fuel oil must be free from any dirt and water which could disturb the stove in operation.
  • Page 9: Recommendation

    Oil fired stove BELFORT 174 05 05 regulator (# 3, fig. 14) with a screwdriver, 3.6. Recommendation - remove the tubular filter from the float regulator. Clean it with oil using a soft brush, never a wire-brush, The adjustment of the stove has been made at the - replace the filter in the float regulator, install the cover factory and checked by your installer.
  • Page 10: Trouble Shooting

    174 05 05 BELFORT Oil fired stove 3.7. Trouble shooting þ : This sign means that you should asked for a qualified engineer to do the work. SYMPTOM PROBLEM −TEST SOLUTION Flames extinguish during ¤ Very cold chimney. No draught −- Leave door ajar until fire has caught.
  • Page 11: Spare Parts

    Oil fired stove BELFORT 174 05 05 4. Spare parts When ordering spare parts, please indicate : model n°, Y = 174 05 05 Y J = 174 05 05 J colour code, description of the part, code of the part. K = 174 05 05 K C = 174 05 05 C Example : Stove 174 05 05 , base 352155 EF...
  • Page 12 174 05 05 BELFORT Oil fired stove Document n° 979-3 EN ~ 28/02/2000 Technical manual...
  • Page 13 Oil fired stove BELFORT 174 05 05 327802 Clamp ......Y ..J ..K ..C ..01 327902 MJ Ash-tray .
  • Page 14 - All installation and adjustment instructions listed in the FRANCO BELGE. Name and address of the installer : _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...
  • Page 15 Belfort Document n° 979-3 NO ~ 28/02/2000 English Parafinkamin Norsk Modell 174 05 05 Norsk DBE Godkjenning no. 006 - 160 Teknisk manual må oppbevares av eier for fremtidig bruk Norsk Importør : Hydro Texaco AS , Telefon 22 12 40 00 Drammensveien 134, Skøyen 0212 Oslo Beskrivelse av kaminen...
  • Page 16 FRANCO BELGE garanterer kvaliteten på sine apparater, alle ISO 9001 godkjent, og forplikter seg til å tilfredstille kundenes ønsker. Med mer enn 75 års erfaring bruker FRANCO BELGE alltid de mest avanserte teknologier i fremstillingen og produksjonen av serien med varmeapparater.
  • Page 17: Beskrivelse Av Kaminen

    174 05 05 BELFORT Parafinkamin 1. Beskrivelse av kaminen 1.1. Beskrivelse Kamin for flytende brensel, med fordampningsbrenner (Norm EN1) - kun for fyringsparafin. 1.2. Emballasje ¤ 1 kamin. 1.3. Tekniske data Modell ..... . 174 05 05 Nominell varmeytelse .
  • Page 18: Brukerveiledning

    Parafinkamin BELFORT 174 05 05 1.4. Brukerveiledning Parafin ledes til brennerbunnen (Fig. 3) hvor den antennes ved hjelp av opptenningsvæske. Varmen som blir produsert av denne flammen, bringer temperaturen i brenner til det nivå som er nødvendig for å fordampe brennstoffet.
  • Page 19: Pipe

    174 05 05 BELFORT Parafinkamin Fig. 6 - Bakdeksel Fig. 5 - Røkutløp på toppen 1 - Røkrør 3 - Skruer, skiver og muttere 2 - Pakning 2.2. Pipe Påse at røkrøret har tilstrekkelig trekk. (Se tekniske spesifikasjoner). Minimum røkrørdiameter 10 cm. Pipen må...
  • Page 20: Oppretting

    Parafinkamin BELFORT 174 05 05 Fig. 9 - Montering av askeskuff Fig. 11 1 - Maks. 3,5 m O l j e l ø f t e r m e d reservetank maks. 20 2 - Min. 0,25 m liter. 3 - Utvendig oljetank 4 - Ventil 6 - Rør...
  • Page 21: Justering Av Oljetilførsel

    174 05 05 BELFORT Parafinkamin 2.11. Justering av oljetilførsel Oljeregulatoren er justert fra fabrikk og trenger ikke ytterligere justering før bruk. Hvis brenneren ikke har tilfredsstillende forbrenning, kontroller først andre muligheter før justering: - Pipetrekk - Frisklufttilgang - Oljetilførsel Kontroll/Justering av lav flamme: (Fig. 12, nr. 2) - Sett regulator på...
  • Page 22: Bruksanvisning

    Parafinkamin BELFORT 174 05 05 3. Bruksanvisning 3.1. Brensel Advarsel : Kaminen er utstyrt med en flottørventil ( r e g u l a t o r ) s o m e r s p e s i f i k t t i l p a s s e t f o r Fyringsparafin.
  • Page 23: Anbefaling

    174 05 05 BELFORT Parafinkamin · Rengjør alle emaljerte deler med en tørr eller lett fuktet 3.5. Vedlikehold av kaminen myk klut. · Bruk en ren myk klut til å tørke av frontglasset mens Hver uke: Benytt hendel for brenner (Fig. 14, nr. 4): kaminen er satt på...
  • Page 24: Feilsøking

    Parafinkamin BELFORT 174 05 05 3.7. Feilsøking þ : Dette tegnet betyr at du må be om kvalifisert bistand for å få arbeidet utført SYMPTOM PROBLEM - FORSØK MED Flamme slokner under Svært kald skorstein. Ingen trekk - - Hold frontdøren litt åpen opptenning etablert - Kontroller at det er tilstrekkelig lufttilgang til rommet...
  • Page 25 174 05 05 BELFORT Parafinkamin 4. Reservedeler Ved bestilling av reservedeler, vennligst angi : Eksempel: Kamin 174 05 05 , Bunnplate 300483 Modell, fargekode, navn og type og del nr. S. 12 nr. del nr. navn ....Type ..Y ..J ..K ..C ..Ant. 100917 Aksling .
  • Page 26 Parafinkamin BELFORT 174 05 05 Document n° 979-3 NO ~ 28/02/2000 Teknisk manual...
  • Page 27 174 05 05 BELFORT Parafinkamin S. 12 nr. del nr. navn ....Type ..Y ..J ..K ..C ..Ant. 327802 Festestykke .
  • Page 28 § Garanti Sertifikat § § Når installasjon og justeringer er utført i henhold til ins- Generell produkt garanti truksjoner i den tekniske manual. Våre produkter har en tolv måneders garanti mot feil eller Når operasjon og vedlikehold er utført i henhold til ins- mangler.

Table of Contents