Signature Command System Operation Instructions - Majestic 400DVBL Installation And Operating Instructions Manual

Dvbl series direct vent gas fireplace
Table of Contents

Advertisement

SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS

SYSTEM CONFIGURATION/SETUP
1. When the master switch is in the ON position ("-"), pressing the ON button and the
OFF button on the Command Center simultaneously will toggle between enabling and
disabling the six-hour shutdown option.
2. After the above operation, one beep (for enabling the six-hour shutdown option) or two
beeps (for disabling the six-hour shutdown option) will be given as confirmation.
Remote Transmitter Learn Function (Default OFF)
1. The RF receiver button located on the control board must be in the on position before the
learn function can begin. Use paper clip to depress button. One beep for RF receiver ON
or two beeps for RF receiver OFF will be given as confirmation.
2. Holding the OFF button on the Command Center while turning on the master switch will
activate the learn function for the transmitter.
3. After the above operation, two beeps will be given and the green LED on the Command
Center will flash for 10 seconds.
4. During the 10 seconds, press the OFF button on a transmitter to learn. Another two beeps
will be given to confirm a successful learning.
Shutting Off the Standing Pilot
To shut off the standing pilot for service or summer shut down, press and hold the ON
button on the Command Center for 3 seconds when the master switch is in the ON position
("-") and the main burner is off.
Note: Pilot will resume the next time system is turned on.
Key Combinations for System Settings
Function
Intermittent/Standing
Pilot Setup
Standing Pilot Temp.
Shutoff
RF Remote Receiver
On/Off
Learn Remote
Transmitter
6-hour safety
shutdown setup
FUNCTIONS/OPERATION
Turning on the fireplace
1. Turn on the master switch and wait for a beep.
2. Press the ON button on the Command Center. Pilot will light and burner will come on
High setting.
Pilot Safety Lockout Function
1. If the pilot doesn't light after sparking for 30 seconds, pilot trial lockout happens. The
LED on the Command Center flashes Green once every 2 seconds.
2. If the pilot flame is lost during normal operation, flame loss lockout happens. The LED
on the Command Center flashes Red-Green once every 2 seconds.
3. Turning off the master switch will reset the system.
4
(continued)
Hold the ON ▲ button while turning on the master switch
(Beep once for standing pilot, twice for intermittent pilot)
Hold the ON ▲ button 3 seconds (when the master switch
on the main burner is off)
Push the RF receiver On/Off button on the control board
Beep once for ON and beep twice for OFF
Hold the OFF ▼ button while turning on the master switch
(Beep twice then press any handheld remote button)
Press the ON ▲ button and OFF ▼ button simultaneously
(Beep once for ON, twice for OFF)
Operation
Default Setting
Intermittent
Pilot
RF OFF
ON
74D0010