Majestic 400DVKHL Installation And Operating Instructions Manual

Dvkhl series direct vent gas fireplace
Table of Contents

Advertisement

Quick Links

DVKHL Series
Direct Vent Gas Fireplace
Models: 400DVKHL & 500DVKHL
Installation and

Operating Instructions

warnInG
IF tHe InFOrMatIOn In tHeSe InStructIOnS IS nOt
FOLLOweD exactLy, a FIre Or expLOSIOn May
reSuLt cauSInG prOperty DaMaGe, perSOnaL
Injury Or LOSS OF LIFe.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
wHat tO DO IF yOu SMeLL GaS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
warnInG: Improper installation, adjustment, alteration,
services or maintenance can cause injury or property
damage. refer to this manual. For assistance or additional
information consult a qualified installer, service agency
or the gas supplier.
this appliance may be installed in an aftermarket*,
permanently located, manufactured home (uSa only) or
mobile home, where not prohibited by local codes.
this appliance is only for use with the type of gas
indicated on the rating plate. this appliance is not
convertible for use with other gases, unless a certified
kit is used.
* aftermarket: completion of sale, not for purpose of resale, from the
manufacturer.
730024
KHLDV cover
Due tO HIGH teMperatureS, tHe appLIance
SHOuLD Be LOcateD Out OF traFFIc anD
away FrOM FurnIture anD DraperIeS.
cHILDren anD aDuLtS SHOuLD Be aLerteD
tO t H e H a Z a r D S O F H I G H S u r Fa c e
teMperature anD SHOuLD Stay away tO
aVOID BurnS Or cLOtHInG IGnItIOn.
yOunG cHILDren SHOuLD Be SuperVISeD
wHen tHey are In tHe SaMe rOOM aS tHe
appLIance.
cLOtHInG Or OtHer FLaMMaBLe MaterIaL
SHOuLD nOt Be pLaceD On Or near tHe
appLIance.
Keep tHe rOOM area cLear anD Free FrOM
cOMBuStIBLe MaterIaLS, GaSOLIne, anD
OtHer FLaMMaBLe VapOrS anD LIquIDS.
InStaLLer: Leave this manual with the appliance.
cOnSuMer: retain this manual for future refer-
ence.
73D0129 2/10 Rev. 13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 400DVKHL and is the answer not in the manual?

Questions and answers

Summary of Contents for Majestic 400DVKHL

  • Page 1: Operating Instructions

    DVKHL Series Direct Vent Gas Fireplace Models: 400DVKHL & 500DVKHL Installation and Operating Instructions warnInG IF tHe InFOrMatIOn In tHeSe InStructIOnS IS nOt FOLLOweD exactLy, a FIre Or expLOSIOn May reSuLt cauSInG prOperty DaMaGe, perSOnaL Injury Or LOSS OF LIFe.
  • Page 2: Table Of Contents

    DVKHL Series Gas Fireplace cOntentS thank you and congratulations on your purchase of a Majestic Fireplace. pLeaSe reaD tHe InStaLLatIOn anD OperatIOn InStructIOnS BeFOre uSInG tHe appLIance! IMpOrtant: read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Important Safety Information

    IMpOrtant SaFety InFOrMatIOn DVKHL Series Gas Fireplace Owner InStaLLer Please retain these instructions for future reference. Please leave these instructions with the appliance. • read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. •...
  • Page 4: Code Approval

    DVKHL Series Gas Fireplace IMpOrtant SaFety InFOrMatIOn and cODe apprOVaL Continued from page 3 IMpOrtant: 15. This appliance, when installed, must be electrically pLeaSe reaD tHe FOLLOwInG grounded in accordance with local codes or in the careFuLLy absence of local codes, with the National Electrical It is normal for fireplaces fabricated of steel to give off Code, ANSI/NFPA 70, or the Canadian Electrical Code, some expansion and/or contraction noises during the...
  • Page 5: Product Features

    11.0” w.c. Inlet Maximum 10.5” w.c. 13.0” w.c. Orifice Size Manifold Pressure 3.5” w.c. 10.0” w.c. Model Fuel Front rear 400DVKHL Nat. #49 (.073") #35 (.110" ) 400DVKHL #56 (.0465") #52 (.0635") 500DVKHL Nat. 2.3 mm #30 (.1285) 500DVKHL #55 (.052") #50 (.070")
  • Page 6: Fireplace & Framing Dimensions

    DVKHL Series Gas Fireplace FIrepLace and FraMInG DIMenSIOnS Min. Rough Opening  Depth 1/2” or 5/8” P - Min. Rough Opening Width Min. Rough Opening Height Figure 2 - Fireplace and Framing Dimensions ref. 400DVKHL 500DVKHL 44ZB\zn" (1141 mm) 48ZB\zn" (1243 mm) 35Z\x" (902 mm) 39Z\x" (1003 mm) 32" (813 mm) 36"...
  • Page 7: Pre-Installation Information

    pre-InStaLLatIOn InFOrMatIOn DVKHL Series Gas Fireplace BeFOre yOu Start FIreBOx FraMInG Read this homeowner manual thoroughly and follow all Firebox framing can be built before or after the appliance instructions carefully. Inspect all contents for shipping is set in place. Refer to Figure 2 for firebox dimensions damage and immediately inform your dealer if any damage and framing.
  • Page 8: Fireplace Location

    DVKHL Series Gas Fireplace pre-InStaLLatIOn InFOrMatIOn FIrepLace LOcatIOn Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e.
  • Page 9: Clearances

    cLearanceS DVKHL Series Gas Fireplace cLearanceS tO cOMBuStIBLeS Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. the appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
  • Page 10: Secure Fireplace

    DVKHL Series Gas Fireplace Secure FIrepLace to FLOOr or FraMInG The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing.
  • Page 11: Venting Installation

    DVKHL Series Gas Fireplace VentInG InStaLLatIOn read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life.
  • Page 12: Installation Planning

    DVKHL Series Gas Fireplace VentInG InStaLLatIOn InStaLLatIOn pLannInG There are two basic types of direct-vent installation: never run the vent pipe level or downward. • this may cause excessive temperatures which Horizontal Termination could cause a fire. • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose.
  • Page 13: Termination Locations

    VentInG InStaLLatIOn DVKHL Series Gas Fireplace GeneraL VentInG InFOrMatIOn - terMInatIOn LOcatIOn INSIDE  CORNER DETAIL  G  V  H  A  D  E  L  C  B  B  V  Fixed B  V  Closed V  Fixed Operable Closed F  V  B  M  V  B  J  B ...
  • Page 14: How To Use The Vent Graph

    DVKHL Series Gas Fireplace VentInG InStaLLatIOn terMInatIOn cLearanceS FOr BuILDInGS wItH cOMBuStIBLe anD nOncOMBuStIBLe exterIOrS G=6" (152mm) F=6" (152mm) Combustible – 6" (152 mm) Noncombustible – 2" (51mm) Inside Corner Outside Corner C = Maximum depth of 48" (1219mm) for alcove location D = Minimum width for back wall of alcove location Combustible - 38"...
  • Page 15: Vertical Sidewall Installation

    VentInG InStaLLatIOn DVKHL Series Gas Fireplace VertIcaL SIDewaLL InStaLLatIOn - twISt LOcK pIpe Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole lo- cation. Depending on whether the wall is combustible or noncombustible, cut opening to size.
  • Page 16: Vertical/Horizontal Termination Configurations

    DVKHL Series Gas Fireplace VentInG InStaLLatIOn VertIcaL/HOrIZOntaL terMInatIOn 36" cOnFIGuratIOnS (914 mm) 24” Max. Since it is very important that the venting system main- (610 mm) tain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent con- figurations apply and must be strictly adhered to.
  • Page 17: Below Grade Installation

    VentInG InStaLLatIOn DVKHL Series Gas Fireplace 90° BeLOw GraDe InStaLLatIOnS When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recom- mended. It allows installation depth down to 7" (178 mm) below grade level.
  • Page 18: Vertical Through-The-Roof Applications

    DVKHL Series Gas Fireplace VentInG InStaLLatIOn If the foundation Restrictor Disc is recessed, use Figure 21 - recess brackets Install Restrictor Disc into Snorkel (not supplied) Fireplace Collar f o r s e c u r i n g Fireplace Foundation lower portion Collar...
  • Page 19: Installation For Vertical Termination

    VentInG InStaLLatIOn DVKHL Series Gas Fireplace example: Elbow 1 90° For optimal flame appearance, a restrictor disk is necessary Elbow 2 45° on straight vertical runs of 10' of more. Elbow 3 45° • Runs may not incorporate elbows. Elbow 4 90°...
  • Page 20 DVKHL Series Gas Fireplace VentInG InStaLLatIOn 4. Connect a section of pipe and extend up through the " hole. " nOte: If an offset is needed to avoid obstructions, you must support the vent pipe every three (3) feet. Use wall straps for this purpose.
  • Page 21: Fireplace Installation

    FIrepLace InStaLLatIOn DVKHL Series Gas Fireplace cHecK GaS type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or con- version kit.
  • Page 22 DVKHL Series Gas Fireplace FIrepLace InStaLLatIOn a manual shutoff valve must be installed Only persons licensed to work with gas upstream of the appliance. union tee piping may make the necessary gas and plugged 1/8" npt pressure tapping connections to this appliance. point should be installed upstream of the appliance.
  • Page 23: Check Gas Pressure - Millivolt

    MILLIVOLt - cHecKInG GaS preSSure and eLectrIcaL InStaLLatIOn DVKHL Series Gas Fireplace 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, StOp! Do not install the appliance.
  • Page 24: Remote Wall Switch Installation - Millivolt

    DVKHL Series Gas Fireplace MILLIVOLt - reMOte waLL SwItcH InStaLLatIOn reMOte waLL MOunteD SwItcH A remote wall switch and up to fifteen (15) feet of 18 Ga. OPTIONAL REMOTE wire may be used with this appliance. Attach the wall WALL SWITCH switch in a junction box at the desired location on the wall.
  • Page 25: Junction Box Wiring

    MILLIVOLt - OptIOnaL Fan/BLOwer SySteM DVKHL Series Gas Fireplace Blue Junction Box Blue Black Right  Hi-Temp Blower 120V AC 60Hz Black Hi-Temp T-Stat Sensor Factory Supplied Left  Not Supplied Blower junction Box Figure 32 - White Black Blower Junction Box Wiring Diagram Figure 33 - Rheostat Blower Wiring Diagram...
  • Page 26 DVKHL Series Gas Fireplace MILLIVOLt - OptIOnaL Fan/BLOwer SySteM Clip Firebox Wall FP2136 FP2137 Figure 35 - Figure 36 - Blower Access Covers FP2136 Blower Access Covers blower access plates FP2137 blower access plates Remove Solid Access Door FP2233 Replace with Louvered Access Door, Louvers Towards Bottom Figure 38 - FP2234...
  • Page 27: Operating Instructions - Millivolt

    MILLIVOLt - OperatInG InStructIOnS DVKHL Series Gas Fireplace FOr yOur SaFety reaD BeFOre LIGHtInG If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. a. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly.
  • Page 28: Lighting Pilot

    DVKHL Series Gas Fireplace MILLIVOLt - OperatInG InStructIOnS LIGHtInG pILOt FOr tHe FIrSt tIMe apprOVeD LeaK teStInG MetHOD If using a soap and water You may check for gas leaks with the following methods solution to test for leaks, only: DO nOt spray solution onto •...
  • Page 29: Lighting Burner

    MILLIVOLt - OperatInG InStructIOnS DVKHL Series Gas Fireplace LIGHtInG Burner MaIn Burner SwItcH The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob.
  • Page 30: Check Gas Pressure - Signature Command

    SIGnature cOMManD - cHecK GaS preSSure and eLectrIcaL InStaLLatIOn DVKHL Series Gas Fireplace 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply Pressure Inlet is different from the fireplace, StOp! Do not install the appliance.
  • Page 31: Junction Box Wiring

    DVKHL Series Gas Fireplace eLectrIcaL InStaLLatIOn junctIOn BOx wIrInG 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing codes. 2. Remove the external junction box cover by removing the screw from the side of the outside firebox wall.
  • Page 32: Electrical Installation

    DVKHL Series Gas Fireplace eLectrIcaL InStaLLatIOn Light 300 Watt To Outlet A/C Module Pilot Optional Blower 300 Watt Rear Burner Solenoid 300 Watt Max RF Receiver A/C Module ON/OFF Button Control Board Black / Thermopile Red / Thermopile Sensor Conversion NG/LP Ignitor / Sparker Plug-in Connector Control Board to Command Center nOte: Wall switch wires must OFF/LO ON/HI be connected together if a wall Master Switch switch is not being used.
  • Page 33: Fan/Blower Systems - Signature Command

    DVKHL Series Gas Fireplace SIGnature cOMManD - OptIOnaL Fan BLOwer SySteM electrical Grounding Instructions: this electrical connections should only be appliance is equipped with a three-prong performed by a qualified licensed electrician. (grounding) plug for your protection against Main power supply must be turned off before shock hazard and should be plugged directly connecting the fan to the main electrical into a properly grounded three-prong...
  • Page 34: Signature Command

    DVKHL Series Gas Fireplace SIGnature cOMManD - OperatInG InStructIOnS FOr yOur SaFety reaD BeFOre LIGHtInG If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. a. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions.
  • Page 35: Operating Instructions

    DVKHL Series Gas Fireplace SIGnature cOMManD - OperatInG InStructIOnS OperatInG InStructIOnS 1. StOp! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3.
  • Page 36: Signature Command System Operation Instructions

    DVKHL Series Gas Fireplace SIGnature cOMManD SySteM OperatIOn InStructIOnS To Thermopile FeatureS RF Receiver ON/OFF To Sensor command center To Sparker • Easy Access Function Operation and System Configura- tion NG/LP • Conversion Operation Confirmation/Fault Diagnostic Indications (LED/Buzzer) • ON/OFF/HI/Med/Low Operation To Command Center control •...
  • Page 37: System Configuration/Setup

    DVKHL Series Gas Fireplace SIGnature cOMManD SySteM OperatIOn InStructIOnS SySteM cOnFIGuratIOn/Setup All System configuration/setup is done on the Command Center. nOte: When using On/Off wall switch, the switch must be in the ON position to perform all configura- tion set ups at the command center. Intermittent/Standing pilot Setup (Default intermittent) 1.
  • Page 38 DVKHL Series Gas Fireplace SIGnature cOMManD SySteM OperatIOn InStructIOnS FunctIOnS/OperatIOn (with command center) turning on the fireplace 1. Turn on the master switch and wait for a beep. 2. Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High set- ting or last memory setting (See Turning Off Fireplace below).
  • Page 39: Touch Screen Remote Control Operation

    tOucH Screen reMOte cOntrOL OperatIOn DVKHL Series Gas Fireplace Due to the sensitive temperature monitoring components in the transmitter, it is necessary to allow the transmitter to stabilize to room tem- perature before accurate room temperatures are displayed. If the transmitter is activated from a severe cold condition, allow 15 minutes for accurate temperature readings to appear on the LcD display.
  • Page 40 DVKHL Series Gas Fireplace tOucH Screen reMOte cOntrOL OperatIOn Setting privacy code on transmitter: Battery Door Figure 51 The remote transmitter privacy code is preset in facto- ry. In the event of activation or interference from other nearby transmissions, change the code using the following procedures (learn function must be performed after changing the code):...
  • Page 41 tOucH Screen reMOte cOntrOL OperatIOn DVKHL Series Gas Fireplace 1. Press the ON/up button to turn on the fireplace. The c. Slide down on the arrow buttons to exit TIMER flame icon on the LCD displays mode and shut off the fireplace. High.
  • Page 42 DVKHL Series Gas Fireplace tOucH Screen reMOte cOntrOL OperatIOn is no manual flame height adjustment. The fan speed will 4. After the signal is sent, the ON/up and OFF/down but- also automatically adjust if turned on. tons become flame height controller again. 5.
  • Page 43: Safety Features

    tOucH Screen reMOte cOntrOL OperatIOn DVKHL Series Gas Fireplace 4. After the signal is sent, the On/up and Off/down but- n Safety Features tons become flame height controller again. 1. Low Battery Detection 5. When the light button is flashing, slide up and down on When low battery condition occurs, the transmitter will the arrow buttons will turn the light brightness to HIGH turn off the fireplace.
  • Page 44 DVKHL Series Gas Fireplace tOucH Screen reMOte cOntrOL OperatIOn n using the Mounting Base The transmitter comes with a mounting base which allows you to hang the transmitter on the wall. 1. Secure the mounting base on the wall with supplied screws.
  • Page 45: Glass Removal

    GLaSS reMOVaL DVKHL Series Gas Fireplace GLaSS FraMe reMOVaL 1. Remove the plate located in front of the glass at the bottom. 2. Remove rod provided for screen assembly located beneath the cover plate. 3. Rotate the access doors on the right and left side of the glass toward the glass. 4.
  • Page 46: Final Installation

    DVKHL Series Gas Fireplace FInaL InStaLLatIOn BrIcK, LIGHt BuLB, anD LenS pLaceMent 1. Remove the trapezoidal light shroud located at the back of the firebox by unfastening the three screws. 2. Disassemble the trapezoidal light shroud by unfastening the four screws which secure the front to the back. Set lens with the orange painted surface toward the bottom.
  • Page 47: Log Placement

    LOG pLaceMent DVKHL Series Gas Fireplace LG593 Burner Grate Assembly LG594 Step 1 LG593 1. Place the rear log over the grate toward the back by positioning the holes over the large pins located KHLDV grate at the right and left. When the log is in place, the back surface of the log will come in contact with LG594 the light trapezoid deflector.
  • Page 48 DVKHL Series Gas Fireplace LOG pLaceMent 4. Place the middle log over the two burners by setting the flat surface over the burner and matching the indenta- tion located underneath the branch over the protrusion located at V-branch on the left front log placed in step #3.
  • Page 49: Cleaning And Maintenance

    cLeanInG anD MaIntenance DVKHL Series Gas Fireplace Sensor turn off gas before servicing fireplace. It is recommended that a qualified service Thermopile technician perform these check-ups at the beginning of each heating season Burner, pILOt anD cOntrOL cOMpart- Ment Signature Keep the control compartment, logs, and burner areas command System pilot...
  • Page 50: Venting System

    DVKHL Series Gas Fireplace cLeanInG anD MaIntenance Vent SySteM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow.
  • Page 51: Troubleshooting

    trOuBLeSHOOtInG DVKHL Series Gas Fireplace StanDInG pILOt IGnItIOn SyMptOM pOSSIBLe cauSe actIOn 1. Spark ignitor will A. Open door and check to make sure wire is connected to A. Wire disconnected. not light pilot after ignitor. repeated triggering of B. Check for spark at electrode and pilot. If no spark and B.
  • Page 52: Troubleshooting

    DVKHL Series Gas Fireplace trOuBLeSHOOtInG StanDInG pILOt IGnItIOn SyMptOM pOSSIBLe cauSe actIOn A. Clean and adjust the pilot flame for maximum flame A. Pilot flame may be too high 4. Frequent pilot impingement on thermocouple. or too low, causing pilot outage problem.
  • Page 53: Signature Command System

    trOuBLeSHOOtInG DVKHL Series Gas Fireplace SIGnature cOMManD SySteM OPERATION FAULT ACTION DIAGNOSIS Using Battery polarity wrong? Re-install batteries battery? Make sure Command Install batteries and/or Battery voltage low? Change batteries Center and plug in the AC board No beep in about the control 8 seconds board are...
  • Page 54: Illustrated Parts Lists

    DVKHL Series Gas Fireplace repLaceMent partS FIreBOx cOMpOnentS anD acceSSOrIeS 12a,b 7a,b Item Description qty. 400DVKHL 500DVKHL Bulb (100 Watt) 73D0020 73D0020 730024 Bulb Socket 73D4521K 73D4521K KHLDV firebox parts Glass Frame Assembly 73D1015K 73D0159K Junction Box Assembly (not shown) 26D2128K 26D2128K...
  • Page 55: Standing Pilot Millivolt Control

    repLaceMent partS DVKHL Series Gas Fireplace StanDInG pILOt — MILLIVOLt cOntrOL 11,12,13,14 730024 khldv mv valve parts 73D0129...
  • Page 56: Replacement Parts

    MVWS Wall Thermostat Kit Forged Andiron 13" FA113 Cast Iron 12 " CAI121/2 Fuel conversion Kits - Millivolt control natural Gas to Lp 400DVKHL Kit #KHL400CKP 500DVKHL Kit #KHL500CKP Lp to natural Gas 400DVKHL Kit #KHL400CKN 500DVKHL Kit #KHL500CKN 73D0129...
  • Page 57: Signature Command System

    DVKHL Series Gas Fireplace repLaceMent partS SIGnature cOMManD SySteM 5a,b,c,d,e 8a,b 7a,b 16,17 730024 KHLDV SG parts 12/08 73D0129...
  • Page 58 (15' Wire, Rough-in Box, Wall Cover) Decorative Door Kit KHL400ADBT KHL400ADBT KHL500ADBT KHL500ADBT Fuel conversion Kits - Signature command System natural Gas to Lp 400DVKHL Kit #KHL400CKPS 500DVKHL Kit #KHL500CKPS Lp to natural Gas 400DVKHL Kit #KHL400CKNS 500DVKHL Kit #KHL500CKNS...
  • Page 59: Logs

    DVKHL Series Gas Fireplace LOGS Item Description qty. 400DVKHL 500DVKHL Log #1 73D0539 73D0200 Log #2 73D0540 73D0201 Log #3 73D0541 73D0202 Log #4 73D0542 73D0203 Log #5 73D0543 73D0204 Log #6 73D0544 73D0205 Log #7 73D0545 73D0206...
  • Page 60: Venting Components

    DVKHL Series Gas Fireplace repLaceMent partS VentInG cOMpOnentS 730024 KHLDV vent parts 73D0129...
  • Page 61 repLaceMent partS DVKHL Series Gas Fireplace VentInG cOMpOnentS FOr 5" 8" current Simpson Simpson Duravent Duravent qty./ or MHSc or MHSc Selkirk Item Box Description part no. part no. part no. Horizontal High Wind Termination Cap 58DVA-HC 1285 5DT-HC Horizontal Termination Cap w/Built-In Vinyl Siding Standoff, BHR8TK Heat Deflector, Firestop and Adjustable Pipe 7"...
  • Page 62: Massachusetts Residents Only

    DVKHL Series Gas Fireplace requirements for the commonwealth of of eight (8) feet above grade directly in line with the exhaust Massachusetts vent terminal for the horizontally vented gas fueled heating This product must be installed by a licensed plumber or appliance or equipment.
  • Page 63: Warranty

    DVKHL Series Gas Fireplace LIMIteD LIFetIMe warranty pOLIcy LIFetIMe warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. FIVe year warranty The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
  • Page 64: Efficiencies

    efficiency ratings Model enerGuide ratings Fireplace efficiency (%) 400DVKHLNV 69.6 400DVKHLPV 78.2 400DVKHLNSC 73.2 400DVKHLPSC 82.2 500DVKHLNV 75.2 500DVKHLPV 69.8 500DVKHLNSC 78.5 500DVKHLPSC 71.8 MHSc 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...