Step 2: Check Installation Hardware; Step 3: Mount Template - GE ZV750 Installation Instructions Manual

36" vent hood
Hide thumbs Also See for ZV750:
Table of Contents

Advertisement

2
Locate the hardware accessory box packed
with range hood and check contents.
Step
Check
Installation
Hardware
Utility Bars with Screws
3
To determine ductwork locations:
• Locate the template packed with the litera-
S tep
ture.
• Determine the exact installation location.
–Measure 36" from the floor to the top of
Ductwork,
the cooking surface. Add 25-1/2" recom-
Wiring,
mended space from the cooking surface to
bottom of hood. Mark that location.
Hood
–Use a level to draw a straight pencil line on
Attachment
the wall.
–Tape the template in position along the
Locations
penciled line. CHECK TO BE SURE
TEMPLATE IS LEVEL.
• Measure from the peak of the hood to the
ceiling as indicated. The dimension should
be:
–26-1/4" to 38-1/4" for 8 ft. to 9 ft. ceilings.
–38-1/4" to 50-1/4" for 9 ft. to 10 ft. ceilings
this installation requires ZX10SY accessory
duct cover.
CEILING DUCTING
If ductwork will vent straight up to the ceiling:
• Use a level to draw a line straight up, from
the centerline on the template to the ceiling.
• Measure 3-1/2" from the back wall to the
centerline of a 6-1/2" dia. hole on the
ceiling.
Note: If drywall is not present, add drywall thickness to the
3-1/2" dimension.
GE Monogram at
Call 1-800-667-8721 anywhere in the US and Canada
2 Mounting
Duct Cover Bracket
2 Phillips Head Screws
::
.
rangehoods
Installation
10
Wall
Fasteners
Brackets
3 Filters
3 1/2"
Centerline To Wall
6-1/2" Dia. Hole
FOR WALL VENT DUCT
WALL DUCTING
If ductwork will vent to the rear:
• Use the level to draw a line straight up from
the centerline on the template.
• Measure at least 6" above the bracket location
shown on the template to the centerline of
the 6-1/2" dia. duct hole. (Hole may need to
be elongated for duct elbow.)
HOUSE WIRING LOCATION:
• The junction box is located on the top of the
hood, at the front right side.
• Route house wiring as close to the installation
location as possible; through the ceiling,
soffit or back wall. Wiring should enter at
least 4" above the bracket on the right side.
com
kitchen
is a division of
U
N
-
36" Vent Hood
2 Large
Flat Washers
10
Wood
Screws
• Drill 1/8" Pilot Holes For Mounting Brackets.
C L
5-7/8"
C L
17-5/16"
C L
• Drill 1/8" Pilot Holes.
Align edge 25-1/2" above Cooking Surface.
Wall Mount Template
FOR CEILING
VENT DUCTING
Centerline
6" Min. Above
Bracket Location
• Drill 1/8" Pilot Holes For Mounting Brackets.
5-7/8"
26-14" to 8 ft. Ceiling
38-1/4" to 9 ft. Ceiling
38-1/4" to 50-1/4" For
9ft. to 10 ft. Ceiling
Using Optional Accessory
ZX10SY Duct Cover
17-5/16"
C L
• Drill 1/8" Pilot Holes.
• Drill 1/8" Pilot Holes.
Align edge 25-1/2" above Cooking Surface.
accessories
::
L
I
M
I
T
E
D
www.rangehoods.com
Decorative
Duct
Cover
26-14" to 8 ft. Ceiling
38-1/4" to 9 ft. Ceiling
38-1/4" to 50-1/4" For
9ft. to 10 ft. Ceiling
Using Optional Accessory
ZX10SY Duct Cover
• Drill 1/8" Pilot Holes.
7

Advertisement

Table of Contents
loading