GE NetworX NX-4 Installation And Startup page 36

Control/communicator
Hide thumbs Also See for NetworX NX-4:
Table of Contents

Advertisement

NX-4 Control
APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID
The NX-4 has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA consists
of an Event Code and a Zone or User ID. The Zone ID will be the zone number that is in alarm. The event code will come
from the chart below and be programmed in the configuration group event code.
Programmed Event Code
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
The NX-4 has the ability to report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code
and a Zone ID. The zone ID is the zone that created the alarm. The event code will come from the chart below and be
programmed in the configuration group event code.
Programmed Event Code
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Page 34
SIA Code
HA
FA
PA
BA
BA
BA
UA
BA
BA
UA
HA
MA
PA
TA
RP
GA
KA
WA
QA
SA
ZA
Contact ID Code
122
110
120
130
131
132
133
134
135
150
121
100
123
137
602
151
158
154
140
140
159
Description
Holdup Alarm
Fire Alarm
Panic alarm
Burglary Alarm
Burglary Alarm
Burglary Alarm
Untyped Alarm
Burglary Alarm
Burglary Alarm
Untyped Alarm
Holdup Alarm
Medical Alarm
Panic alarm
Tamper Alarm
Periodic Test
Gas Alarm
Heat Alarm
Water Alarm
Emergency Alarm
Sprinkler Alarm
Freeze Alarm
Description
Silent Panic
Fire Alarm
Panic alarm
Burglary Alarm
Perimeter Alarm
Interior Alarm
24 Hour Burglary
Entry Alarm
Day/Night Alarm
Non Burglary 24 Hour
Duress Alarm
Medical Alarm
Audible Panic Alarm
Tamper Alarm
Periodic Test
Gas Detected
High Temp
Water Leakage
General Alarm
General Alarm
Low Temp