8. Specifications

E
Model
Item
Cooling*2 capacity
BTU/h
Total input
Heating*3 capacity
BTU/h
Total input
Model name
Power supply*1
Air flow (Lo-Hi)
CMM
Fan Noise level (Lo-Hi)
dB (A)
Motor output
Booster heater
Dimensions (H × W × D)
mm
Weight
Dimensions (H × W × D)
mm
Weight
Model name
Power supply*1
Air flow
CMM
Fan
Motor output
Compressor motor output
Crankcase heater
Dimensions (H × W × D)
mm
Weight
Noise level
dB (A)
Notes: *1 Refer to the product nameplate attached to the unit for the electrical specifications.
*2 Rating conditions (cooling)
*3 Rating conditions (heating) Indoor
*4 These data based on indicated voltage. 1ph, 240V
*5 Specifications subject to change without notice.
Operating range
Indoor air intake temperature
Maximum
35°C DB, 22.5°C WB
Cooling
Minimum
21°C DB, 15.5°C WB
Maximum
27°C DB
Heating
Minimum
20°C DB
Units should be installed by licensed electric contractor accordingly to local code requirement.
PLH-2KKC
W
18300
kW
W
20500
kW
PLH-2KKC
~ (1ph), 240V, 50Hz
13 - 16
32 - 37
kW
0.030
kW
253 × 660 × 660
kg
30 × 760 × 760
kg
PUH-2AKA
~ (1ph)
kW
0.065
kW
W
650 × 870 × 295
kg
Indoor
:
27°C DB, 19°C WB
:
21°C DB
Outdoor air intake temperature
46°C DB
–5°C DB
21°C DB, 15.5°C WB
–8.5°C DB, –9.5°C WB
5350
2.32
6000
2.29
19
3.7
240V
50Hz
45
1.7
38
64
49
Outdoor :
Outdoor :
PLH-2.5KKC
6200
21200
2.54
6900
23500
2.30
PLH-2.5KKC
~ (1ph), 240V, 50Hz
14 - 17
35 - 39.5
0.030
253 × 660 × 660
20
30 × 760 × 760
3.7
PUH-2.5AKA
~ (1ph)
240V
50Hz
50
0.085
2.0
38
850 × 870 × 295
68
52
35°C DB
7°C DB, 6°C WB
19