Plumbing Requirements - AGA marvel M60CFWR-SS Installation, Operation And Maintenance Instructions

Built in side by side by side freezer/wine cellar/refrigerator
Table of Contents

Advertisement

Available languages

Available languages

Plumbing Requirements:

Ice maker water supply line,
copper tubing to come up the rear of cut out opening ap-
proximately 78" (198.1cm) off the floor depending on height
adjustment. Tubing should then pass around the right side
of the power module and around the front to the water sole-
noid valve. See Figure 6.
On model M72CTWT-SS two (2) water lines will be re-
quired as there are two ice makers. This can be accom-
plished by running two separate lines or by providing a tee
in the line to go to one of the ice makers. See Figure 7.
When installing the water line for the ice maker, be sure
to install a SHUT-OFF VALVE at a convenient location
between the freezer and the supply line. Required water
pressure range is 20 to 120 psi (138 to 827 kPa).
Also recommended is an in-line WATER FILTER between
the freezer and the supply line to prevent sediment from
blocking water flow through the water solenoid valve.
An ideal location for these items is on top of the cabinet,
behind the grill, and to the right of the power module. See
Figures 6 and 7.
"A"
Recommended
location of
water line
78" (198.1cm)
approximately
Figure 6
Recommended location
of water line
PRE INSTALLATION CONSIDERATIONS
" (6.4mm) outside diameter
1
4
NOTE
Self-piercing water valves and plastic tubing are NOT ap-
proved for water supply to ice maker.
Model
M60CFWR-SS
20" (50.8cm) to
M72CFWR-SS
20" (50.8cm) to
M72CFWR-WS
20" (50.8cm) to
M72CFSWR-WS
20" (50.8cm) to
M72CFWR-WP
20" (50.8cm) to
M72CTWT-WS
Table A
"A"
24" (61cm)
Recommended location
10
"A"
"B"
17
" (43.8cm)
-
1
4
-
23" (58.4cm)
-
23" (58.4cm)
-
23" (58.4cm)
-
23" (58.4cm)
68" (172.7cm) to
23" (58.4cm)
71" (180.3cm)
"B"
Recommended
location of
water line
78" (198.1cm)
approximately
Figure 7