GROUNDING METHOD AND ELECTRICAL REQUIREMENTS
Toe kick (Front Grille)
Figure 3
Toe kick screw
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Do not splash or spray water from a hose on the refrigera-
tor! Doing so may cause an electrical shock, which may
result in severe injury or death.
This unit should not, under any circumstances, be installed
to an un-grounded electrical supply.

Grounding Method

This product is factory equipped with a power supply cord that
has a three-pronged, grounded plug. It must be plugged into a
mating grounding type receptacle in accordance with the Na-
tional Electrical Code and applicable local codes and ordinances
(see Figure 4). If the circuit does not have a grounding type re-
ceptacle, it is the responsibility and obligation of the customer to
provide the proper power supply. The third ground prong should
not, under any circumstances, be cut or removed.

Electrical Requirements

Electrical Requirements: A 115 volt, 15 amp dedicated circuit is
required. A 3 prong grounded receptacle is required.
The unit must be installed according to your local building codes
and ordinances.
5
Do not use an extension cord with
this appliance.
Figure 4