Trouble shooting
Problem
Smoke from the grate at start
up.
Smoke from closed doors
The fan doesn´t start
Tar in the convetion area.
None or little heat is transfer-
red to the accumulator.
The boiler gives less effect
and is hard to use
The laddomat valve is bang-
ing or making strange noices,
poor flue through the system.
The pressure is decreasing in
the system
Effecta AB - Västra Rågdalsvägen 21 - 434 96 Kungsbacka - 0300 - 22320 - info@effecta.se
Possible faults
The fan is not running.
Seals leaky
Faulty control panel.
Overheating protection released.
Too much soot in the grate.
Lambda sond dirty
Dampers faulty
Air in the system.
Poor wood.
Moisty wood, to little
draft through the chimney.
The boiler needs to be cleaned.
Air in the system,
To low pressure in the system
You have a leak in the system.
Water have vaporised from the
open expansion vessel. Wrong
pre-pressure in the pressure
vessel.
Action
Press ( Start ).
Adjust doors, replace seals.
Contact Effecta.
Press the reset pin under the
hat.
Clean grate
Clean lambda sond
Contact Effecta
Try to deair the system
Switch to better wood, or split
it finer.
Try wood with less moist.
Clean the boiler
Try to deair the system
Increase pressure
Check for the leak.
Fill the system.
Adjust pressure.