Valve Combination
The valve combination is mounted on the domestic water circuit. It´s
purpose is to mix the hot water with cold before it reaches the water
taps. This is to avoid burns, and to keep the taps and seals from be-
ing destroyed by to hot water.
Piping
Normally copper is used for installing these systems. Piping between
OBS !
boiler and accumulators should not be less 8mm. If the piping is
longer than 6 meters to the first tank it´s recomended to use 35mm.
Tänk på att alltid isolera
rörledningar i systemet.
The Accumulator Tank
Effecta Lambda must always be connected to some sort of accumu-
lator tank, where the energy is stored, and where the domestic water
and the warm water to the radiators is taken. The accumulator is
described more thorough on page 13.
The Draft Stabiliser
If you have a tall and wide chimney, it´s possible that you have to
install a draft stabiliser. You might notice that you have an irregular
combustion, puffing sounds from the boiler. This happens when the
chimney sucks too much air through the boiler. The placement of the
draft stabiliser in the chimney should be approx. one meter above
the connection to the boiler. This is because you have an overpres-
sure from the fan, and if you place the draft stabiliser too close to the
boiler you might have smoke coming out of the stabiliser.