Installing The Switch; Selecting A Site - Edge-Core ECS3610-28T Installation Manual

Table of Contents

Advertisement

3
I
S
ELECTING A
Switch units can be mounted in a standard 19-inch equipment rack or on a flat
surface. Be sure to follow the guidelines below when choosing a location.
The site should:
restrict access to authorized service personnel in accordance with IEC
60950-1. A restricted access location is one where access is secure and
limited to service personnel who have a special key, or other means of
security
be at the center of all the devices you want to link and near a power
outlet
be able to maintain its temperature within 0 to 40 °C (32 to 104 °F)
and its humidity within 5% to 95%, non-condensing
provide adequate space (approximately five centimeters or two inches)
on all sides for proper air flow
be accessible for installing, cabling and maintaining the devices
allow the status LEDs to be clearly visible
Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical interference,
such as radios and transmitters.
Make sure that the unit is connected to a separate grounded power outlet
that provides 100 to 240 VAC, 50 to 60 Hz, is within 2 m (6.6 feet) of each
device and is powered from an independent circuit breaker. As with any
equipment, using a filter or surge suppressor is recommended. Verify that
the external power requirements for the selected option can be met as
listed under
NSTALLING THE
S
ITE
"Power Supply" on page 68
S
WITCH
.
– 37 –