Chapter 3: Installing the Switch

Selecting a Site

This unit can be mounted in a standard 19-inch equipment rack or on a flat surface.
Be sure to follow the guidelines below when choosing a location.
• The site should:
- restrict access to authorized service personnel in accordance with IEC 60950-1.
A restricted access location is one where access is secure and limited to service
personnel who have a special key, or other means of security.
- be at the center of all the devices you want to link and near a power outlet.
- be able to maintain its temperature within 0 to 45 °C (32 to 113 °F) and its
humidity within 10% to 90%, non-condensing
- provide adequate space (approximately five centimeters or two inches) on all
sides for proper air flow
- be accessible for installing, cabling and maintaining the devices
- allow the status LEDs to be clearly visible
• Make sure twisted-pair cable is always routed away from power lines, fluorescent
lighting fixtures and other sources of electrical interference, such as radios and
transmitters.
• Make sure a separate grounded power outlet that provides 100 to 240 VAC, 50 to
60 Hz is within 2.44 m (8 feet) of the unit and is powered from an independent
circuit breaker. As with any equipment, using a filter or surge suppressor is
recommended.

Ethernet Cabling

To ensure proper operation when installing the switches into a network, make sure
that the current cables are suitable for 10BASE-T, 100BASE-TX or 1000BASE-T
operation. Check the following criteria against the current installation of your
network:
• Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables
with RJ-45 connectors; Category 3 or better for 10BASE-T, Category 5 or better
for 100BASE-TX, and Category 5 or better for 1000BASE-T.
• Protection from radio frequency interference emissions
• Electrical surge suppression
• Separation of electrical wires (switch related or other) and electromagnetic fields
from data based network wiring
• Safe connections with no damaged cables, connectors or shields
3-1