Reassembly:
(a) Fit the Housing Pump O-ring to the Outer Bowl.
When replacing or refitting the pump housing, a new
O-ring must be fitted.
(c) Refit the Pump Housing.
Note: This should be done with the Pump Cap & Hood
in place, but it is not essential.
(c) Press the pump to its home position as much as
possible by hand, then use the bolts to evenly torque
the pump down.
(d) Tighten the pump bolts to a torque of 2Nm.
Note: If the bolts happen to strip when refitting the
pump housing, refer to the Pump Housing – Stripped
Pump Housing Procedure (refer to Section 11.1).
Pump Assembly
69
478182
Outter Tub
O'Ring