160.
(10100000) Basket Engaged In Agitate
The bowl has re-engaged itself during agitate.
Primary Source:
Action:
Secondary Source: Installation (drain) set up
Action:
Tertiary Source:
Action:
220.
(11011100) EEPROM Model Map Not Programmed
On power up, the Motor Control Module has detected a fault in its memory.
Primary Fault:
Action:
230.
(11100110) EEPROM Value out of Range
Wrong version detected
Primary Fault:
Action:
232.
(11101000) COMMS Timeout 5 Sec
IW only problem, either the Display or Motor Control Module has not responded in time.
Primary Fault:
Action:
Secondary Fault:
Action:
233.
(11101001) EEPROM Read Error
Problem in reading the EEPROM data, coming from the Motor Control Module.
Primary Fault:
Action:
234. (11101010) Lid Lock Open Circuit.
Check harness to Lid Lock, the connections at the Motor Control Module and lid lock ends.
Primary Fault:
Action:
Secondary Source: Lid lock has failed to be activated.
Action:
Tertiary Source:
Action:
Mechanical.
1) Check that the rotating basket assembly is not jammed to the
agitator with any foreign object that may be caught under the
agitator skirt.
2) Check that the clutch teeth are not locked together with dirt, lint,
etc.
3) Make sure the basket is not overloaded with too many clothes.
4) If none of the above appears to be at fault, then check the air bell
at the bottom of the inner basket for leaks.
Check that the drain hose is fitted into the drain caddy and extends
no more than ¾" (20 mm) from the end. Check if fitted to a stand pipe
that the drain hose is not pushed down to far.
Motor Control Module.
If the machine is empty of water at fault, it is possible that the pump
circuit is faulty and has caused a pump out during wash. This would
cause the basket to re-engage during agitate and the Motor Control
Module to display this fault. Replace Motor Control Module.
Motor Control Module.
Change Motor Control Module.
Motor Control Module is the wrong version.
Change Motor Control Module.
Display Module fault.
Replace Display Module.
Motor Control Module fault.
Replace Motor Control Module.
Motor Control Module fault.
Replace Motor Control Module.
Connectors on the harness at either end could be at fault.
Replace Harness.
Replace Lid Lock Assembly.
Motor Control Module has not responded to the lid lock being
activated.
Check the lid has a tang and is fitted correctly to activate the lid lock.
If this is all in order, the Motor Controller must be faulty and needs
replacing.