• With the blower housing open, there is easy access to the
flue pipe exiting the rear of the unit. Figure 5.7. Vacuum
the flue pipe as far into the pipe as possible. NOTE: Be
careful while cleaning the flue pipe not to bend the exhaust
probe. The ESP is approximately 8" into the tube and is
visible when looking into the exhaust.
Be careful not to damage probe when cleaning with brush.
Figure 5.7
18
ESP
Harman® • Accentra Owner's Manual_R40 • 2002 -___ • 11/15
G. Pellet Feeder Chamber
Figure 5.8
Feeder Chamber
This chamber may get a buildup of fines from the feeder
mechanism movement. This area should be checked and
cleaned at least once a year.
To remove the feeder cover:
• Remove the (2) 5/16" wing nuts.
• Slide the cover off of the threaded studs.
• Inspect and clean the inner chamber if necessary. See
above picture.
• Reinstall the cover making certain it is centered on the
feeder body and tighten the wing nuts as tightly as you
can by hand.
NOTE: Views are shown with the rear motor covers
removed.
Possible pellet fines buildup area.
3-90-08326c