12 - 18 DS3578 With FIPS Digital Scanner Product Reference Guide
Digit or Fill (8)
The data validator accepts any numeric or fill character in this position.
Template
88899
Alpha or Fill (F)
The data validator accepts any alpha or fill character in this position.
Template
AAAFF
Required Space ( )
When this option appears in the template string, the template accepts a space if present. Optional characters are
not allowed as the first character(s) in a field of like characters.
Template
99 99
8
Valid data
Valid data
12345
>>789
Valid data
Valid data
ABCXY
LMN>>
Space
Valid data
Invalid data
12 34
67891
Invalid data
<<789
F
Invalid data
ABC<5