and COMPONENT IDENTIFICATION/LOCATION
A. SPECIFICATIONS (Natural Gas Only)
MAXIMUM CAPACITY (DRY WEIGHT)
BASKET (TUMBLER) DIAMETER
BASKET (TUMBLER) DEPTH
BASKET (TUMBLER) VOLUME
DRIVE MOTOR
DOOR OPENING (DIAMETER)
DOOR SILL HEIGHT - LEVEL
COMPRESSED AIR VOLUME *
COMPRESSED AIR CONNECTION
VOLTAGE AVAILABLE
BLOWER MOTOR
HEAT INPUT
APPROX. WEIGHT (UNCRATED)
AIRFLOW
INLET PIPE SIZE
Shaded areas are stated in metric equivalents
*
Air volume requirement is 11 cfh (0.31 cmh) for tilting models.
** Tilt gas dryers must be provided with clean, dry, and regulated air at 80 PSI +/- 10 PSI (5.51 bars +/- 0.68
bars).
NOTE: Dryers must be provided with a clean, dry, and regulated 80 PSI +/- 10 PSI (5.51 bars +/-
0.68 bars) air supply (equivalent volume = 11 cfh [0.31 cmh]).
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
SECTION II
SPECIFICATIONS/DIMENSIONS
310 lbs.
62-1/2"
60"
106.5 cu. ft.
5 HP
36-3/4" w x 43" h
36-1/2"
11 cfh
3/8" F.P.T.
208-600v 3ø 3, 4w 50/60 Hz
15 HP
1,125,000 btu/hr
5,100 lbs.
6,500 cfm
1-1/2" F.P.T. (1)
6
141 kg
158.75 cm
152.4 cm
3.02 cu. m.
3.73 kw
93.3 cm x 109.2 cm
92.71 cm
0.31 cmh
11.25 kw
283,500 kcal/hr
2,313 kg
184 cmm