Advertisement

Quick Links

Installation Manual
WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion and to prevent property
damage, personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Clear the room, building or area of
all occupants.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
AD-45x2(R)(i)
AVERTISSEMENT: Assurez-vous de
bien suivre les instructions données dans
cette notice pour réduire au minimum le
risque d'incendie ou d'explosion ou pour
éviter tout dommage matériel, toute
blessure ou la mort.
—Ne pas entreposer ni utiliser d'essence
ni d'autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
—QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter d'allumer d'appareils.
Ne touchez à aucun interrupteur. Ne
pas vous servir des téléphones se
trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la
zone.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
—L'installation et l'entretien doivent être
assurés par un installateur ou un
service d'entretien qualifié ou par le
fournisseur de gaz.
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781 USA
Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447
e-mail: techsupport@amdry.com
www.adclaundry.com
ADC Part No. 113540 -5

Advertisement

Table of Contents
loading

Summary of Contents for ADC AD-45x2

  • Page 1 American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447 e-mail: techsupport@amdry.com www.adclaundry.com ADC Part No. 113540 -5...
  • Page 2 Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory, you can FAX your order to ADC at +1 (508) 678-9447 or telephone your order directly to the ADC Parts Department at +1 (508) 678-9000. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.
  • Page 3: Table Of Contents

    WARNING In the State of Massachusetts, the following installation instructions apply: Proposition 65 Installations and repairs must be performed by Use of this product could expose you to a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of substances from fuel combustion that contain Massachusetts.
  • Page 4: Safety Precautions

    Safety Precautions ___________________ WARNING WARNING The collection of lint in the burner area and exhaust ductwork can create a potential fire hazard. For your safety, the information in this manual must be followed to minimize the risk of fire or explosion For personal safety, the dryer must be electrically grounded or to prevent property damage, personal injury, or loss in accordance with local codes and/or the National Electrical...
  • Page 5 CE ONLY IMPORTANT: This appliance must only be installed and operated in the country of destination indicated on the dryer’s data plate. If the appliance is to be installed and operated in a country other than the one indicated on the data plate, a data plate amendment must be obtained from American Dryer Corporation.
  • Page 6: Specifications

    Specifications _____________________________________________________________________ 20.4 kg MAXIMUM CAPACITY (DRY WEIGHT) 45 lb PER POCKET TUMBLER DIAMETER 32-3/4” 83.2 cm 76.2 cm TUMBLER DEPTH 30” TUMBLER VOLUME 14.6 cu ft 413.4 L PER POCKET TUMBLER / DRIVE MOTOR 1/3 hp 0.25 kW PER POCKET 0.37 kW BLOWER / FAN MOTOR 1/2 hp...
  • Page 7 Specifications _____________________________________________________________________ NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. 113540 - 5 www.adclaundry.com...
  • Page 8: Installation Procedures

    Installation Procedures ______________ Dryer must be exhausted to the outdoors in an area where correct exhaust venting can be achieved as noted in this Installation should be performed by competent technicians in manual (refer to Exhaust Requirements section). accordance with local and state codes. In the absence of Dryer must be located in an area where correct exhaust venting these codes, the installation must conform to applicable can be achieved as noted in this manual (refer to Exhaust...
  • Page 9: Fresh Air Supply Requirements

    Fresh Air Supply Requirements ______ Exhaust Requirements _______________ This appliance may only be installed in a room that meets the IMPORTANT: Dryer should be located where a minimum appropriate ventilation requirements specified in the national amount of exhaust duct will be necessary. installation regulations.
  • Page 10 IMPORTANT: The dryer exhaust duct must not be If the length of the duct run or quantity of elbows used exceeds connected to any gas vent, chimney, wall, ceiling, or the above noted specifications, the cross-sectional area of concealing space of a building. the ductwork may need to be increased.
  • Page 11: Electrical Information

    Electrical Information ________________ Electrical Service Specifications Gas Models Only Electrical Requirements ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET) All electrical connections must be made by a properly licensed and competent electrician. This is to ensure that the electrical IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
  • Page 12: Gas Information

    Single-Phase (1ø) Wiring NOTE: Undersized gas piping will result in ignition Connections / Hookup problems, slow drying, increased use of energy, and can create a safety hazard. The electrical input connections on all single-phase (1ø) gas dryers are made into the junction box located at the top left The dryer must be connected to the type of heat/gas indicated side area of the dryer (refer to page 7).
  • Page 13: Preparation For Operation / Start-Up

    Preparation for Operation / Start-Up _ Piping Connections All components/materials must conform to National Fuel Gas The following items should be checked before attempting to Code Specifications ANSI Z223.1-LATEST EDITION, or in operate the dryer: Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA- Read all “caution,”...
  • Page 14: Preoperational Instructions

    Service / Parts Information __________ IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be regulated at the Service source (L.P. tank) or an external regulator must be added to each dryer. Service must be performed by a qualified trained technician, service agency, or gas supplier.
  • Page 15: Routine Maintenance

    (sensor bracket) area. issued for merchandise damaged in transit. WARNING All returns should be shipped to the ADC factory in such a manner that they are insured and a proof of delivery can be obtained by the sender.
  • Page 16: Adjustments

    ADC. This information is on the data label affixed to the right side panel area at the rear of the dryer. When contacting ADC, please have the model number and serial number available. 1. MODEL NUMBER – This describes the style of dryer and type of heat (gas, electric, or steam).
  • Page 17: Coin Programming

    Coin Programming ____________________ Accessing and Clearing Coin Vault Total Enter program mode by switching program switch (up) while Enter Programming Mode By Placing no cycle is in progress. The Programming Switch On The Phase 7 Board Up While No Cycle Is In Progress. Press HI –...
  • Page 18 ADC Part No. 113540 5 - 06/11/14...

This manual is also suitable for:

Ad-45x2rAd-45x2ri

Table of Contents