[406] Number of Rings to Answer On
Program the number of consecutive rings that panel must detect to answer for downloading. Valid entries are [000] to [010].

[499] PC-Link Communications

Enter the following command to initiate downloading via PC-Link: [499] [Installer Code] [499]. Plugging in the PC-Link connector will
automatically initiate the connection if DLS is initiated before connecting the PC-Link Header. The session will NOT be automatically initi-
ated if the system is in installer mode.
[501] to [514] Programmable Output Attributes
These options are used to customize the operation of the PGM outputs ([501] for PGM 1, [502] for PGM 2 etc.). The available options
depend on which PGM output type has been programmed.
When the PGM Output Options ([009] to [011]) are programmed, the system will change the PGM Attributes to the default settings. The
PGM Attributes will default if a new PGM output option is programmed.
PGM Output Option [01], [03] to [08], [11] to [22], [25],[26], [28], [30], [33], [34]
Option
Description
[3]
: the PGM output will operate normally (switch to ground when activated).
ON
OFF: the PGM output will be grounded and switch to open collector (open circuit) when activated.
PGM Output Option [19] to [22]
Option
Description
[4]
: the PGM output will activate for the duration of the PGM Output Timer when the [][7][x] command is performed.
ON
OFF: the PGM output will latch until the [][7][x] command is performed again.
: a valid user code must be entered after the [][7][x] command. OFF: a user code is not required.
[5]
ON
PGM Output Option [09]
Option
Description
[1]
: PGM output is activated if a Service Required trouble condition is present.
ON
[2]
: PGM output is activated if an AC trouble condition is present.
ON
[3]
: PGM output is activated if a Telephone Line trouble condition is present.
ON
[4]
: PGM output is activated if a Failure to Communicate trouble condition is present.
ON
[5]
: PGM output is activated if a Zone Fault condition is present.
ON
[6]
: PGM output is activated if a Zone Tamper condition is present.
ON
[7]
: PGM output is activated if a Wireless Low Battery trouble condition is present.
ON
[8]
: PGM output is activated if a Loss of Clock trouble condition is present.
ON
PGM Output Option [10]
Option
Description
[1]
ON
: PGM output is activated if a Burglary Alarm occurs.
[2]
ON
: PGM output is activated if a Fire Alarm occurs.
: PGM output is activated if a Panic Alarm occurs.
[3]
ON
: PGM output is activated if a Medical Alarm occurs.
[4]
ON
: PGM output is activated if a Supervisory Alarm occurs.
[5]
ON
: PGM output is activated if a Priority Alarm occurs.
[6]
ON
[7]
: PGM output is activated if a 24-Hour Hold-Up Alarm occurs.
ON
[8]
: the PGM output is activated for the time programmed for the PGM Output Timer.
ON
OFF: the PGM output will latch until a valid user code is entered.
PGM Output Option [31]
Option
Description
[1]
: PGM output is activated if a Fire Alarm occurs.
ON
[2]
: PGM output is activated if a Panic Alarm occurs.
ON
[3]
: PGM output is activated if a Burglary Alarm occurs.
ON
[4]
ON
: PGM output is activated if an Opening/Closing occurs.
: PGM output is activated if a zone is automatically bypassed.
[5]
ON
[6]
: PGM output is activated if a Medical Alarm occurs.
ON
[7]
: PGM output is activated if both a confirmed alarm and a Police Code occur.
ON
[8]
ON
: the PGM output is active when the selected condition is true. OFF: the PGM output will latch until a valid user code is entered.
23