OBSERVED PROBLEM
ODS/pilot lights, but flame
goes out when control knob is
released.
Burner does not light after
ODS/pilot is lit.
Burner backfi res during com-
bustion.
Slight smoke or odor during
initial operation.
Logs appear to smoke after
initial operation.
Heater produces a whistling
noise when burner is lit.
No gas to pilot.
Blower does not work.
WARNING:
soot and the heater may backfi re when lit. If the gas quality or pressure is low, contact
your local gas supplier immediately.
WARNING:
use only parts specifi cally approved with this appliance may result in property damage
or personal injury.
36
POSSIBLE CAUSE
1. Control knob not fully pressed in.
2. Control knob not pressed in long
enough.
3. Manual shutoff valve not fully open.
4. Thermocouple connection loose at
control valve.
5. Pilot fl ame not touching thermocou-
ple, which allows thermocouple to
cool, causing pilot fl ame to go out.
This problem could be caused by
either low gas pressure, or a dirty
or partially clogged ODS/pilot.
6. Thermocouple damaged.
7. Control valve damaged.
1. Burner orifi ce is clogged.
2. Burner orifi ce diameter is too small.
3. Inlet gas pressure is too low.
1. Manifold pressure is too low.
2. Burner orifi ce is clogged.
1. Burner orifi ce is clogged or dam-
aged.
2. Burner is damaged.
3. Gas regulator defective.
1. Vapors from paint or curing process of
logs.
2. Vapors or smoke continue after
heater is run with damper or window
open for several hours.
1. Turning control knob to HIGH posi-
tion when burner is cold.
2. Air in gas line.
3. Dirty or partially clogged burner ori-
fi ces.
1. LP-regulator shut down due to inlet
pressure too high.
1. Power cord not plugged in.
2. Loose wire connections.
3. Defective blower thermostat.
If the gas quality is bad, your pilot may not stay lit, the burners may produce
Failure to position the parts in accordance with these diagrams or failure to
TROUBLESHOOTING
SOLUTION
1. Press in control knob fully.
2. After ODS/pilot lights, keep control knob pressed
in for 30 seconds.
3. Fully open manual shutoff valve.
4. Hand tighten thermocouple connection until
snug, then tighten 1/4 turn more.
5a.Contact local gas company.
5b.Clean pilot with vacuum cleaner.
6. Replace thermocouple.
7. Replace control valve.
1. Clean orifi ce.
2. Replace burner orifi ce.
3. Contact qualifi ed service person.
1. Contact local gas company.
2. Clean burner or replace burner orifi ce.
1. Clean burner or replace burner orifi ce.
2. Replace burner.
3. Replace gas regulator.
1. Problem will stop after a few hours of operation.
Run the heater with the damper open if you have
one, or open a window for the fi rst few hours.
2. Log heater is intended to be smokeless. Turn
OFF heater and call qualifi ed service person.
1. Turn control knob to LOW position and let warm
up for a minute.
2. Operate burner until air is removed from line.
Have gas line checked by local gas company.
3. Clean burner or replace burner orifi ce.
1. Verify LP tank regulator is installed and set at
11" to 13" w.c.
2. Replace regulator on heater.
1. Plug power cord into junction box found in lower
access level.
2. Check wire connections, reconnect if loose.
3. Replace thermostat.