Checking Burner Flame; Operating Instructions - Vermont Castings VFC24C Installation & Operating Instructions Manual

Vfc vent free fireplace system
Table of Contents

Advertisement

VFC Vent Free Fireplace System

CHECKING BURNER FLAME

VFC24L/VFC32L MODELS
In normal operation at full rate after 15 minutes, the
following fl ame appearances should be observed:
Burner will have a random pattern of yellow fl ames. Figure
32. There should be glowing embers in front of burner.
NOTE: The front fl ames and embers will be an opaque
orange color during the burn off time.
VFC24C/VFC32C MODELS
In normal operation at full rate after 15 minutes, the
following fl ame appearances should be observed:
Burner will have a random pattern of yellow fl ames. Figure
33
Figure 32 -
VFC Traditional Flame Appearance
Figure 33 -
VFC Contemporary Flame Appearance
28

OPERATING INSTRUCTIONS

Avoid any drafts that alter burner fl ame patterns. Do
not allow fans to blow directly into the fi replace. Do not
place a blower inside the burn area of the fi rebox. Ceiling
fans may create drafts that alter fl ame patterns. Sooting
and improper burning will result.
During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils,
fi lms or bonding agents. These chemicals are not harmful,
but may produce annoying smoke and smells as they are
burned off during the initial operation of the appliance,
possibly causing headaches or eye or lung irritation. This
is a normal and temporary occurrence.
The initial break-in operation should last two to three hours
with the burner at the highest setting. Provide maximum
ventilation by opening windows or doors to allow odors to
dissipate. Any odors remaining after this initial break-in will
be slight and will disappear with continued use.
This appliance must not be used with glass doors in the
closed position. This can lead to pilot outages and severe
sooting outside the fi replace.
FLAME APPEARANCE