Premium Upgrade Kits

#157498 - NG
#157499 - LP
Kit Contents:
• Flame Control (LP or NG)
• Accent Lamp Kit
• Blower Kit with Multifunction Remote
READ THESE INSTRUCTIONS BEFORE BEGINNING
INSTALLATION. INSTALL EACH COMPONENT IN THE ORDER
PRESENTED HERE.
SEE PAGES 30-33 FOR REMOTE CONTROL OPERATION.
WARNING:
DISCONNECT THE POWER SUPPLY AND TURN OFF THE
MAIN GAS SUPPLY TO THE STOVE BEFORE INSTALLING
REMOTE CONTROLLED ACCESSORIES.
Flame Control Installation
f i r e - p a r t s . c o m
1. Using a Torx T-20 screwdriver, remove the two screws
from the front of the manual regulator and remove
those components as shown in fig. 41.
2. Confirm the appropriate fuel type by the label on the
Flame Control motor. Install the motor using the new
screws included with the kit.
3. Connect the wire harness to terminal (M) on the front
side of the IFC board, fig. 41.
4. If appropriate, follow the instructions for fuel
conversion beginning on page 17.
M
Figure 41. Flame Control Motor installation.

Accent Lamp

Contents:
1. Lamp Box Assembly w/ harness
2. Lens
3. Gasket
4. Light Deflector Plate - not used
with GF 500 DV IPI
1. Remove the stove top plate and Top Convection
Shroud.
2. Remove the two flanged hex head bolts (A) and cover
plate from the Relief Panel using a 10 mm socket or
wrench. See fig. 42.
3. Position the Gasket, Lens, and Lamp Box over the
opening on the Relief Panel using the two bolts (A)
previously removed.
4. Route the controls wire harness over and down
between the heat shield and the left cast iron side.
Connect the harness to the ( L ) terminal on the rear
of IFC board. See figs. 43 - 44. Loosen the IFC board
wing nut and pull the board back to improve access to
the terminal.
See Remote Control operation instructions on pages 30-33.
A
Lamp Box
Lens
Gasket
Figure 42. Accent Lamp installation.
Figure 43. Accent Lamp Harness routing.
139636_02 GF 500 DV IPI January 2015
Tools Required:
• 10 mm wrench
• Safety goggles
• Work gloves