The rotor can not be tested
Perform all other test to eliminate all other possible problems before replacing the rotor.
This brushless designed rotor has integrated diode rectifiers. When the rotor rotates in the stator, AC
voltage is generated in the rotor windings. The AC voltage is sent to the diode rectifiers (located on the
rotor) and is converted to DC voltage producing a rotating magnet. While the rotating magnet field
passes through the main windings located in the stator, this produces AC Voltage – 120V AC.
GA – Series Rotor