SYMPTOM
Generator will not start: or
starts and runs rough
Engine backfires
Engine runs good at no-
load but "bogs down"
when loads are applied.
T
R
O
U
B
L
E
T
R
O
U
B
L
E
POSSIBLE PROBLEM
Fuel valve is in the "Off"
position or partially closed
Engine switch is in the "Off"
position
Low oil level
Fuel delivery system
Flooded
Carburetor inadequate air
supply
Intake valve stuck open or
closed
No spark
Defective anti-backfire
solenoid
Engine speed is to low
Generator is overloaded
Short circuit in a connected
load
Carburetor inadequate
Multiquip Inc. ◦ GA Series Generators ◦ Manual No. GAGENSM
S
H
O
O
T
I
N
G
S
H
O
O
T
I
N
G
For more on engines see engine
manufactures manual or you may
contact one of our Technical Support
coordinators at (888) 661-8992
Turn fuel valve to the "On" position
Set switch to the "On" position
Fill crankcase to proper oil level or
place generator on level surface.
Check fuel filter and ensure fuel flow to
carburetor is sufficient. Also check fuel
tank for contaminated or stale fuel,
replace if necessary.
Wait 5 minutes and re-crank engine
Check or replace clogged air filter
Inspect valves and valve clearance
Check condition of spark plug and
ignition coil. Inspect wires to the on / off
switch.
Check solenoid see pg.24
Raise engine speed to rated RPM
Check connected device amperage is
application sufficient
Disconnect shorted electrical device
Check or replace clogged air filter
Ensure carburetor jets are not clogged
SOLUTION