Electrical Service Guide - Miller Electric 230Volt Owner's Manual

Arc welding power source with built-in synergic control 230/460 and 460/575 volt models
Table of Contents

Advertisement

4-5. Electrical Service Guide

NOTICE − INCORRECT INPUT POWER can damage this welding power source. This welding power source requires a CONTINUOUS supply of
input power at rated frequency(+10%) and voltage (+10%). Phase to ground voltage shall not exceed +10% of rated input voltage. Do not use a genera-
tor with automatic idle device (that idles engine when no load is sensed) to supply input power to this welding power source.
NOTICE − Actual input voltage should not be 10% less than minimum and/or 10% more than maximum input voltages listed in table. If actual input
voltage is outside this range, output may not be be available.
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG
Reference: 2005 National Electrical Code (NEC) (includes article 630)
1 Consult factory for circuit breaker applications.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
Notes
OM-188 304 Page 16
1
2
Time-Delay
3
Normal Operating
4
4
60 Hz Three Phase
230
460
575
31
15
12
35
15
15
45
20
20
10
14
14
112
175
274
(34)
(53)
(83)
10
14
14
60 Hz Single
Phase
230
460
53
27
60
30
80
40
8
10
85
224
(26)
(68)
8
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

460volt575voltInvision 354mp

Table of Contents