5-3. Overload Protection
1
Push And Turn
2
Pull Out And
Push And Turn
Replace F1
If fuse F1 opens, the robot interface
shuts down. To check or change
F1, proceed as follows:
3
1
Fuse Holder Cover
2
Fuse F1 (See Parts List For
Rating)
3
Circuit Breaker CB1
CB1 protects the wire feed motor
from overload. If CB1 opens, the
wire feed motor stops. Check for
jammed wire, binding drive gear, or
misaligned drive rolls. Correct
problem.
Allow cooling period and manually
reset breaker.
Ref. ST-800 185-A / ST-119 644-B
OM-884 Page 23
Need help?
Do you have a question about the A.B.B. Robot Interface Gas Control Hub And Spindle and is the answer not in the manual?