ELECTRICAL FEEDER CABLE CONNECTION
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
To connect the supply cable:
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A"
(figure 7.2).
Open the cable gland by unscrewing screw "F" (fig. 7.3), unscrew the terminal screws
and remove the cable.
The new supply cable, of suitable type and section, is connected to the terminal board
following the diagram of fig. 7.4.
NOTE: The earth conductor must be left about 3 cm longer than the others.
POWER SUPPLY
230 V~ 50 Hz
FEEDER CABLE SPECIFICATIONS
Type "H05RR-F"
3 x 1,5 mm
2
28
2350 W
A
Fig. 7.2
230 V
L
N
E
E
Earth
N
Neutral
L
Live
Fig. 7.4
F
Fig. 7.3