PrEPArInG tHE CountErtoP

The countertop must have a deep flat surface
to accommodate the cooktop and the vent .
Countertops with a rolled front edge and
backsplash may not provide the flat surface
area required .
25" min . flat surface area required
Clearance between inside front of cabinet and
rear of countertop cutout must be 20
accommodate cooktop depth .
"
2
min .
3
8
A 1/2" wide flat area is required around the edge
of opening for support of the unit . The cooktop
unit must be level and sit squarely into countertop
opening .
Carefully cut countertop opening according to the
dimensions shown in the illustration . Be sure that
opening is cut squarely, with sides parallel to each
other and rear exactly perpendicular to sides .
"
25
Installation Instructions
CABInEt PrEPArAtIon CutoutS
" in order to
5
8
"
20
5
8
1
7
"
20
5
8
"
28
7
8
"
1
min .
7
8
PrEPArInG For DuCtWorK
4
notE: Ductwork muSt be vented to outside.
Do not vent into a wall, ceiling, crawlspace, attic or any
concealed space.
Cut hole in cabinet wall or floor as appropriate for your
installation . Make sure exhaust duct is located between wall
studs or floor joists .
notE: When cutting or drilling into wall or ceiling,
do not damage electrical wiring and other hidden utilities.
"
9
1
8
Rear Wall Venting
"
min .
8
BloWEr to DuCtWorK AlIGnmEnt
5
In general, the use of flexible ducting is discouraged because
it can cause severely restricted airflow . However, if the
blower outlet and the floor or wall duct location do NOT align
well, then flexible METAL ducting can be used to adapt to an
offset . Good alignment without use of flexible ducting is best .
notE:
• Do not exceed the maximum recommended offset of 6" .
• Do not allow the flexible ducting to kink or collapse .
• Do stretch the flexible ducting as much as possible to
eliminate as much of the corrugation as possible .
Bottom Venting
A 3
" x 10" rectangle to 6" round transition duct is available
1
4
at your local building supply store .
notE: Illustrations are for planning purposes only.
19
"
18
3
4
"
10
1
8
Downward Venting
6" Max .
Centerline
to
Centerline
Offset
Back Venting
(Requires 3
" x 10")
1
4
"
6
1
8