PRECAUTIONS AND GENERAL GUIDELINES FOR MAINTENANCE OF TOOLS
1. Safety glasses must be worn at all times when using the tool.
WARNING: Keep fingers clear of dies and ram during tool operation.
Do not operate tool without dies and connector in place.
DO NOT USE THIS TOOL ON LIVE ELECTRICAL CIRCUITS
2. Be sure to select appropriate dies to suit the connector to be crimped. Improper combinations result in inferior con-
nections of conductors.
NOTE: DIES
ARE
PANDUIT CONNECTORS. CONNECTIONS WITH PANDUIT CONNECTORS UTILIZING THIS TOOL ARE
U.L. LISTED AND C.S.A. CERTIFIED ONLY WHEN USING PANDUIT COPPER AND ALUMINUM COM-
PRESSION CONNECTORS. USE OF ANY OTHER BRAND OF COMPRESSION CONNECTORS IS NOT
RECOMMENDED.
3. Always keep fingers out of die set area in crimp head.
4. Always verify the proper size connector for the conductor, by checking the color code and the printing on
the connector.
5. If the tool is kept in cold temperatures below 23°F/-5°C for any extended time, it is advisable to return the
tool to room temperature for 1 hour before using.
6. Keep the tool head portion clean and free from debris. Excessive dirt and grit can contribute to the premature wear of
the tool's internal parts. Always replace the dust cap on the connector fitting, and store the tool in its clean, dry carry-
ing case when not in use. When using the tool, regularly check that no foreign matter or debris exists in the open areas
between the ram and tool head. Solvent can be used on the tool head to remove any foreign matter or debris. A tool
that is dirty with excessive foreign matter may jam and become damaged during operation.
7. To ensure a quality connection, the CT-930CH and CT-940CH Tools must be used with a hydraulic pump capable of
developing and sustaining 10,000 PSI pressure. These tools are matched with PANDUIT 's CT-901HP Hydraulic Pump
and CT-900HPH Hydraulic Hose system.
The CT-930LPCH Tool must be used with a hydraulic pump capable of developing and sustaining 7,500 PSI pressure.
This tool is matched with PANDUIT 's CT-8250HP Hydraulic Pump and CT-900LPHPH Hydraulic Hose system.
Consult PANDUIT Sales for Hydraulic Pump and Hose specifications.
8. Avoid dropping the tool. Extreme shock may damage the hydraulic circuit or tool head, and result in malfunction of the
tool.
9. As long as the daily maintenance procedures are adequately carried out, the tool will provide quality service for years.
However, if problems are experienced, please contact PANDUIT' s Tool Service Department at 1-888-506-5400, ext.
3255.

DIE SELECTION

Match index number and color on die (see figures on Page 5) to index number and color band on connector.
NOTE: Consult your PANDUIT catalog or Sales Office for wire size, crimp designations, U.L. listing and C.S.A. certifica-
tion (where applicable) of connections using the CT-930CH, CT-930LPCH and CT-940CH Tool.
CT-930CH, CT-930LPCH and CT-940CH OPERATING INSTRUCTIONS
DESIGNED
TO
PRODUCE
THE
HIGHEST
Page: 3 of 6
QUALITY
CONNECTIONS
WITH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct-940chCt-930lpch

Table of Contents