Inspection of Compression Force ......... . . 7 NOTE: In the interest of higher quality and value, PANDUIT is constantly improving and updating our products.
Page 2
). PANDUIT recommends using their CT-901HP Hydraulic Pump and CT-900HPH 10 foot Hydraulic Hose. • The CT-930CH and CT-901HP Hydraulic Pump System can crimp #8 AWG thru 750 kcmil PANDUIT Copper Compression Connectors and #6 AWG thru 600 kcmil PANDUIT Aluminum Compression Connectors. PANDUIT' s CT-930CH Tool develops up to 14 tons (12.7 metric tons) of compressive force.
Page 3
CD-940CH: CD-940-DA Die Adapter: To be used with CD-920 and CD-930 series dies CG-920 Compression Gauge: Verifies the compression force of the CT-930CH and CT-930LPCH tools. CG-940 Compression Gauge: Verifies the compression force of the CT-940CH tool. CT-900HPH or Electrically non-conductive 10 ft.
Page 4
7. To ensure a quality connection, the CT-930CH and CT-940CH Tools must be used with a hydraulic pump capable of developing and sustaining 10,000 PSI pressure. These tools are matched with PANDUIT 's CT-901HP Hydraulic Pump and CT-900HPH Hydraulic Hose system.
Page 5
CT-930CH, CT-930LPCH and CT-940CH OPERATING INSTRUCTIONS DIE IDENTIFICATION FOR USE WITH MATCHED CONNECTOR 1. Always verify correct die set by die part number. 2. Color coding dot for verification may be found near die crimp pocket. DIE COLOR CODE AND DIE...
Page 6
TOOL OPERATION (See figures above) 1. The CT-930CH and CT-940CH Tool Heads must be operated with a compatible hydraulic pump system, capable of developing and sustaining 10,000 PSI (700 kg/cm2). PANDUIT 's CT-901HP Hydraulic Pump and CT-900HPH High Pressure Hose (electrically non-conductive; 10 foot long) is recommended. This system's fittings are matched to the tool head fittings.
Page 7
6. Verify that the conductor size and dies properly match the connector size being used. Insert the conductor complete- ly into the connector barrel. 7. Begin crimping by activating the hydraulic system. The PANDUIT CT-901HP and CT-8250HP Hydraulic Pumps incor- porate a by-pass valve which, when activated, shuts off the pump when the crimp is completed.