Keep the tool head and tool body portion clean and free from debris. Soap and a damp cloth should be used
to clean the tool body.
Always store the tool in its clean, dry carrying case when not in use.
DO NOT press trigger and release button simultaneously. Damage to trigger linkage may result.
DO NOT let the ram contact the crimp head.
Always point tool away from others.
If the tool is kept in cold temperatures below 23
to room temperature for 1 hour before using.
Always verify the proper size connector for the conductor, by checking the color code and the printing on the
connector.
Avoid dropping the tool. Extreme shock may damage the hydraulic circuit and result in malfunction of the tool.
NOTE:
CONNECTIONS UTILIZING THIS TOOL ARE U.L. LISTED AND C.S.A. CERTIFIED ONLY WHEN
PANDUIT COPPER COMPRESSION CONNECTORS ARE USED. USE OF ANY OTHER BRAND OF
COMPRESSION CONNECTORS IS NOT RECOMMENDED.

DIE SELECTION

NOTE:
DIES ARE DESIGNED TO PROVIDE THE
HIGHEST QUALITY CRIMPING WHEN USED WITH
PANDUIT COMPRESSION CONNECTORS.
USE OF ANY OTHER BRAND OF CONNECTORS IS
NOT RECOMMENDED WITH CD-920, CD-930 OR
CD-940 DIES.

MAINTENANCE

It is recommended that the hydraulic fluid be changed every 24 months. The tool should be returned to PANDUIT
Tool Division for proper oil changing.