Download Print this page

IHP RHAPSODY RHAP42N Installation Instructions Manual

For gas conversion kits for use with rhapsody linear direct vent gas fireplaces with sit proflame systems

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS FOR GAS CONVERSION KITS FOR USE WITH
RHAPSODY
®
LINEAR DIRECT VENT GAS FIREPLACES WITH SIT PROFLAME SYSTEMS
[FIREPLACE MODELS RHAP42N, RHAP54N]
HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL
COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
• Fireplaces surfaces get EXTREMELY HOT!
• Install only when fireplace is OFF and COLD.
• The glass on the front of the fireplace reaches EXTREMELY HIGH temperatures
and can cause severe burns if touched. Even after the gas is turned off, fireplace
surfaces remain extremely hot.
• Keep children away from an operating fireplace. Closely supervise children in
any room where a fireplace is operating to prevent contact with glass.
RISK OF PERSONAL INJURY OR PROPERTY DAMAGE.
• Never operate fireplace with glass door assemblies removed.
f i r e - p a r t s . c o m
• Securely tighten door latch screws when reinstalling glass door assemblies to
prevent doors from falling out.
• Handle glass door assemblies with extreme care. Replace damaged glass door
assemblies with approved replacement assemblies only.
• The door assemblies contain ceramic glass. Handle with care to prevent
damage. If the door frame or glass becomes damaged, replace the entire glass
door assembly with a manufacturer-approved replacement assembly only. Do
not attempt to substitute any materials used on door assemblies or replace
cracked or broken glass with any other materials.
KIT CONTENTS
• (2) Brass Burner Orifices
• (1) Pilot Orifice
• (1) SIT Regulator Conversion Kit
• (2) Gas Conversion
Information Labels
REQUIRED TOOLS
• 5/32 in. Allen Wrench
• Torx Bit (T20 with 1/4 in. shank) or
Flat-head Screwdriver
• 1/2 in. Open-End Wrench
Description
Model No.
Natural Gas to
GCK-RAPNP
Propane
Table 1: Gas Conversion Kits
GENERAL INFORMATION
Gas conversion kits adapt the appliance
from the use of one type of gas to
another. This kit contains all components
required to complete the conversion,
as well as a self-adhesive label with gas
conversion information to apply to the
appliance rating plate.
• Before installing gas components, apply
pipe joint compound or Teflon tape to
all pipe fittings. Always use propane-
resistant joint compounds. Never use
pipe joint compounds on flare fittings.
P506019-90
P/N 506019-90 Rev. B 05/2015
WARNING
CAUTION
• The burner orifices provided in this
kit are only for use at elevations of
0–4,500 ft (0–1372 m) in the U.S.A.
and Canada. At higher elevations,
the BTU input must be derated by
4% for every 1,000 ft (305 m) to
maintain the proper ratio of gas to
air. If the installer must convert the
unit to adjust for varying altitudes,
a deration information sticker must
be completed by the installer and
attached to the appliance at time of
conversion. Contact your local gas
supplier for deration requirements
Cat.
for your area.
No.
In Canada:
H8540
• The conversion shall be carried out
in accordance with the requirements
of the provincial authorities having
jurisdiction and in accordance
with the requirements of the CAN/
CSA-B149.1 Installation code.
Au Canada:
• La conversion devra être
effectuée conformément aux
recommandations des autorités
provinciales ayant juridiction et
conformément aux exigences du
code d'installation CAN/CSA-B149.1.
NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT DRAWN TO SCALE.
HEARTH PRODUCTS
KITS AND ACCESSORIES
GAS CONVERSION KIT
RHAPSODY
®
LINEAR / SIT PROFLAME
WARNING
RISK OF PERSONAL INJURY,
DEATH, OR PROPERTY DAMAGE.
This conversion kit shall be installed
by a qualified service agency in
accordance with the manufacturer's
instructions and all applicable codes
and requirements of the authority
having jurisdiction. If the information
in these instruction is not followed
exactly, a fire or explosion or
production of carbon monoxide may
result, causing property damage,
personal injury, or loss of life. The
qualified service agency is responsible
for the proper installation of this
kit. The installation is not proper
and complete until the operation of
the converted appliance is checked
as specified in the manufacturer's
instructions supplied with the
kit.The qualified service agency
performing this installation assumes
responsibility for this conversion.
AVERTISSEMENT
RISQUE DE BLESSURE, MORT OU
DOMMAGE À LA PROPRIÉTÉ
Cette trousse de conversion doit être
installée par un technicien agréé,
selon les instructions du fabricant
et selon toutes les exigences et tous
les codes pertinents de l'autorité
compétente. Assurez-vous de bien
suivre les instructions dans cette
notice pour réduire au minimum
le risque d'incendie, d'explosion
ou la production de monoxyde
de carbone pouvant causer des
dommages matériels, des blessures
ou la mort. Le tecnicien agréé est
responsable de l'installation de
cette trousse. L'installation n'est
pas adéquate ni complète tant que
le bon fonctionnement de l'appareil
converti n'a pas été vérifié selon les
instructions du fabricant fournies avec
la trousse. Le fournisseur de service
qualifié ayant réalisé l'installation
assume les responsabilités liées à la
conversion.
1
1 1

Advertisement

loading

Summary of Contents for IHP RHAPSODY RHAP42N

  • Page 1 HEARTH PRODUCTS KITS AND ACCESSORIES P506019-90 GAS CONVERSION KIT P/N 506019-90 Rev. B 05/2015 RHAPSODY ® LINEAR / SIT PROFLAME INSTALLATION INSTRUCTIONS FOR GAS CONVERSION KITS FOR USE WITH RHAPSODY ® LINEAR DIRECT VENT GAS FIREPLACES WITH SIT PROFLAME SYSTEMS [FIREPLACE MODELS RHAP42N, RHAP54N] WARNING WARNING...
  • Page 2: Installation Instructions

    INNOVATIVE HEARTH PRODUCTS • RHAPSODY ™ LINEAR GAS FIREPLACES WITH SIT PROFLAME • GAS CONVERSION KIT INSTALLATION INSTRUCTIONS 5. Remove the three (3) screws WARNING / AVERTISSEMENT securing the lower edge of the glass door assembly to the fireplace. BURN HAZARD. Install only when fireplace is OFF and COLD. 6.
  • Page 3 INNOVATIVE HEARTH PRODUCTS • RHAPSODY ™ LINEAR GAS FIREPLACES WITH SIT PROFLAME • GAS CONVERSION KIT INSTALLATION INSTRUCTIONS Remove two screws to remove burner assembly. Burner Assembly Venturi Right Burner Bracket Burner Orifice f i r e - p a r t s . c o m Control Compartment Access Panel and Gasket Right Burner Bracket...
  • Page 4 INNOVATIVE HEARTH PRODUCTS • RHAPSODY ™ LINEAR GAS FIREPLACES WITH SIT PROFLAME • GAS CONVERSION KIT INSTALLATION INSTRUCTIONS 11. Refer to Figure 7 and the 16. Verify the new burner orifice is the 20. Place the burner assembly into instructions provided with the SIT correct size.
  • Page 5 INNOVATIVE HEARTH PRODUCTS • RHAPSODY ™ LINEAR GAS FIREPLACES WITH SIT PROFLAME • GAS CONVERSION KIT INSTALLATION INSTRUCTIONS Flame Appearance and Sooting Air Shutter Adjustment Guidelines Igniter Rod Pilot Hood • If smoke or soot is present, push Proper flame appears blue at the base the lever IN to increase the air and becomes yellow-orange in the body shutter gap.
  • Page 6 Consult your local distributor for fireplace code information. 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 Printed in U.S.A. © 2015 Innovative Hearth Products P506019-90 P/N 506019-90 Rev. B 05/2015 IHP.us.com NOTE: DIAGRAMS AND ILLUSTRATIONS ARE REPRESENTATIVE AND ARE NOT DRAWN TO SCALE. IHP.us.com...

This manual is also suitable for:

Rhapsody rhap54n