Auto Switch Off Setting [ SLEEP ]
Auto Sleep Settings can also be configured in the acaia APP.
1. The number indicates the amount of time before the scale enters sleeping mode. For example,
when 10 is selected, the scale enters sleeping mode after 10 minutes of idling.
2. Press
button to toggle through the options.
3. Press and hold
confirm the selected option.
Zero Tracking Setting [ trAcE ]
Zero Tracking is a function for maintaining the zero indication within certain limits automatically.
1. OFF: It is not recommended to turn off the Zero Tracking because the zero indication would
draft easily as room temperature changes.
2. 0.5d~3d: For example, for standard resolution each division is 0.1g, 3d = 0.3g. When Zero
Tracking is set to be 3d, any initial weight between +/- 0.3g on the weighing pan would be
zeroed out gradually.
3. 2d is recommended in general for acaia Lunar Coffee Scale.
4. Press and hold
confirm the selected option.
Key Sound Setting [ bEEP ]
Key Sound Settings can also be configured in the acaia APP.
1. Set the Key Sound function off to turn off the beeping sound or on to turn on the beeping sound.
2. Press and hold
confirm the selected option.