3.4.12
Blow Function Setting
BLOW function: After the unit is turned off, water in evaporator of indoor unit will be automatically evaporated to
avoid mildew.
In cooling and dry mode, press Function button till the unit enters BLOW function, with
BLOW blinking, and then press Enter/cancel button to turn on this function.
In BLOW mode, press Function button till the unit enters BLOW function and then press
Enter/cancel button to cancel this function.
BLOW function setting is shown in Fig.3.4.12
Note:
1.After setting BLOW function, turn off the unit by pressing On/Off button on remote controller, indoor fan will run
at low fan speed for 10 min. (BLOW shows).Meanwhile, if BLOW function is canceled indoor fan will be turned
off directly.
2.There is not BLOW function in fan or heating mode.