Antenna Motor Removal - Viking VCSO210SS Service Manual

Combi-steam convect oven
Hide thumbs Also See for VCSO210SS:
Table of Contents

Advertisement

VCSO210SS
1. REMOvAL
1. Disconnect the power supply cord, and then remove the
outer case and the back plate assembly.
2. Open the door and block it open.
3. Wait for 60 seconds to discharge the high voltage
capacitors of the inverter unit.
4. Disconnect the high voltage wire from the magnetron
terminal with insulated pliers.
5. Make the terminal (metal part) of the high voltage wire
contact to the magnetron body with insulated pliers.
6. Now, the capacitors of the inverter unit are discharged.
WARNiNG: Use the pliers that the portions of their handles
are insulated completely to avoid an electric
shock.
7. Remove the bottom plate, referring to "BOTTOM
PLATE REMOVAL".
8. Disconnect the wire leads from magnetron.
9. Remove the two (2) screws holding the bottom shield
plate to the oven cavity with the magnetron.
10.Remove the two (2) screws holding the magnetron
to the waveguide.
11. Remove the magnetron from waveguide.
12.Now, the magnetron is free.
1. Disconnect the power supply cord.
2. Wait for 60 seconds to discharge the high voltage
capacitors of the inverter unit.
3. Remove the outer case cabinet, referring to
"OUTER CASE REMOVAL".
4. Remove the one (1) screw fixing the sirocco motor to the
steam duct.
5. Hold the left end of the sirocco motor and pull it toward
you to remove it from the steam duct.
The antenna motor can be changed with the cabinet installed.
1. Disconnect the power supply cord.
2. Wait for 60 seconds to discharge the high voltage
capacitors of the inverter unit.
3. With the oven upside down, cut the six (6) ribs to
separate the antenna motor cover from the rest of the
bottom plate.
MAGNETRON REPLACEMENT
SiROCCO MOTOR REMOvAL

ANTENNA MOTOR REMOvAL

30
2. REiNSTALLTiON
1. Reinstall the magnetron to waveguide flange with the
two (2) screws.
2. Reinstall the bottom shield plate with magnetron by the
two (2) screws.
3. Reinstall the bottom plate assembly to the oven with
eleven (11) screws.
4. Reconnect the wire leads to the magnetron, convection
heater, convection motor and thermal cut-outs.
5. Reinstall outer case and check that the oven is operating
properly.
CAUTiON: WHEN REPLACING THE MAGNETRON, BE
SURE THE R.F. GASKET IS IN PLACE AND
THE MAGNETRON MOUNTING SCREWS
ARE TIGHTENED SECURELY.
Steam duct
Sirocco motor
4. Disconnect the terminal from the antenna motor.
5. Remove the two (2) antenna motor screws and
remove the antenna motor.
NOTE: When reinstalling the antenna motor cover, rotate
cover 180° to align with screw hole and tabs. Use
two (2) screws (LX-BZA171WREZ) along one edge
of the cover.
Steam duct cover ORG
Screw
Steam duct angle