When removing and/or loosening the oven hinges such as in door replacement, the following adjustment criteria are
taken. Door adjustment is performed with the door properly installed and closed and while the oven hinges are loose.
1. Loosen the screws holding the oven hinge right and the
oven hinge left to the bottom plate with screwdriver.
Screws
2. Insert a spacer of 0.8mm in thickness between the door
sealer section (lower portion) and the front plate.
Spacer
Door cam
Sealer
3. Adjust the door by moving it so that the door is parallel
with the oven cavity front plate lines (right and left side
lines) and the door latch heads pass through the latch
holes correctly.
4. Tighten the screws holding the right oven hinge to the
bottom plate. Then tighten the screws holding the left
DOOR SENSiNG SWiTCH, SECONDARY/THiRD iNTERLOCK SWiTCH, AND MONiTOR SWiTCH
1. REMOvAL
1. Disconnect the power supply cord.
2. Remove the outer case cabinet, referring to
"OUTER CASE CABINET REMOVAL".
3. Open the oven door and block it open.
4. Wait for 60 seconds to discharge the high voltage
capacitor of the inverter unit.
5. Disconnect the wire leads from the switch.
6. Remove each one (1) screw holding the latch hook (right
or left) to the oven cavity front plate, and release the
latch hook (right or left).
7. Keep pushing the stopper tab holding the switch to the
latch hook (right or left) and revolve the switch on the
pole.
8. Remove the switch from the latch hook (right or left).
9. Now, the switch is free.
2. REiNSTALLATiON
1. Reinstall the switch in its place. The door sensing switch
is in the lower position of the latch hook left. The third
door switch is in the upper position of the latch hook left.
The monitor switch is in the upper position of the latch
hook right. The secondary interlock switch is in the lower
position of the latch hook right.
DOOR ADJUSTMENT
Screws
Oven
cavity
front
Door cam
oven hinge to the bottom plate.
5. Adjust the latches (see [Switch adjust]).
NOTE: In order to prevent deformation of parts, lay a soft
mat and then flip the oven onto its back plate.
1. After adjustment, make sure of the following:
1. The door latch heads smoothly catch the latch hooks
through latch holes and the latch heads goes through
center of latch holes.
2. The door is positioned with its face pressed toward oven
cavity front plate.
3. Reinstall the outer case cabinet and check for micro
wave leakage around the door with an approved micro
wave survey meter. (Refer to Microwave Measurement
Procedure.)
NOTE: The door on a microwave oven is designed to act as
an electronic seal preventing the leakage of mi
crowave energy from the oven cavity during cook
cycle. This function does not require that the door
be airtight, moisture (condensation)-tight or light-
tight. Therefore, occasional appearance of moisture,
light or sensing of gentle warm air movement
around the oven door is not abnormal and do not of
themselves indicate a leakage of microwave en
ergy from the oven cavity. If such were the case,
your oven could not be equipped with a vent, the
very purpose of which is exhaust the vapor-laden
air from the oven cavity.
2. Hold the latch hook (right or left) to the oven cavity front
plate with the one (1) screw.
3. Reconnect the wire leads to the switch ((refer to page 32
for each switch terminal location)
4. Make sure that the monitor switch is operating properly
and check continuity of the monitor circuit. Refer to
page 12 PRIMARY INTERLOCK SYSTEM TEST-
checking switches
Latch Hook Left
3rd Door
Switch
Door Sensing
Switch
25
VCSO210SS
Latch Hook Right
Monitor Switch
Secondary
Interlock
Switch

Hide quick links: