Water Supply/Drainage Schematic - Viking VCSO210SS Service Manual

Combi-steam convect oven
Hide thumbs Also See for VCSO210SS:
Table of Contents

Advertisement

1. When installing the reservoir
FEED-WATER RESERVOIR
2. When steaming and supper steam convection operations

WATER SUPPLY/DRAiNAGE SCHEMATiC

ENGINE UNIT ASSEMBLY
Water level sensor
Water level unit
DEW TRAY
Inserting the reservoir delivers water to the water level unit.
Turning the heater ON generates steam.
Dew condensation water in the oven cavity and the exhaust air
duct is discharged to the dew tray
9
VCSO210SS
Water supply tube
to the engine as-
sembly
TUBE PUMP
Activation of the
pump delivers
water to the
engine through
the tube.